The three inputs and their correspondent view presets are independent from one to another. Therefore, with the connections to three sensors, installer can set up camera to monitor three different spots with different dwell time.
Presets For Events
Default settings at the
If setting(s) is / are done to presets 17, 18 and 19 :
At the trigger of
At the trigger of
At the trigger of
If one or more positions of presets 17, 18 and 19 is / are empty:
At the trigger of alarm 1, lens will move to preset 1 (preset 17 is empty)
At the trigger of alarm 2, lens will move to preset 2 (preset 18 is empty)
At the trigger of alarm 3, lens will move to preset 3 (preset 19 is empty)
Note:
All the three alarm inputs are TTL level and triggered by negative signals.
To utilize the default view positions, user must
Alarm-ON Management Protocol
With the presetting of its internal software, the PTZ camera will perform the following functions automatically at the triggering(s) to
Camera is running
1.When the first alarm signal hits this camera, lens will move to the
corresponding presets (see relative information on above ) at maximum speed of 300o per second
2.Lens will stay at the preset position for 60 seconds
3.Camera will be back to the original
4.In case second and third alarm kicks in during the 60 seconds, camera will move to the corresponding preset(s) and stay for 10 seconds initially, then move to the next
5.Camera will be back to its original
. | . |