Connect the
Video signal from the dome is sent to DVR also, then forwarded to monitor through the multiplexer inside the DVR. Usually RG59 A/U coaxial cable is recommended for the video connection.
Power (DC12V or AC24V) shall be applied to the camera via separate DC or AC adapter.
Set the termination resistor in speed dome to OPEN mode (disconnected) if only one speed dome is connected console.
If two or more speed domes are in the system, the termination resistor of END unit should be loaded (more information is in the next section).
Select a proper protocol and corresponding baud rate for the DVR. Be sure both sides (PTZ camera and DVR) have the same protocol and baud rate.
In case the DVR does not have PTZ control function, use a separate keyboard for the PTZ controlling. Protocol shall be properly selected, too.
. | . |
User’s manual | 33 |