MAINTENANCE

Spark Arrester

WARNING

Failure to heed the following warnings while servicing the spark arrester could result in serious injury or death. Never run the engine in an enclosed area. Remove any combustible materials from the area. Wear eye protection and leather work gloves. Do not stand behind or in front of the vehicle while purging. Never go under the vehicle while it's inclined.

The exhaust system can get extremely hot. Do not perform service on the spark arrester while the system is hot. Allow components to cool sufficiently before proceeding.

Use the following procedure to periodically purge accumulated carbon from the exhaust pipe/muffler.

1.Remove the arrester clean- out plug from the bottom of the muffler.

2.Place the transmission in PARK.

3.Start the engine.

4.Quickly squeeze and release the throttle lever several times to purge carbon from the system.

5.If carbon comes out of the exhaust, cover or plug the exhaust outlet(s). Wear protective gloves.

Clean-Out

Plug

6.Lightly tap on the exhaust pipe with a rubber mallet while repeating step 4.

7.If particles are still suspected to be in the muffler, elevate the rear of the vehicle one foot (30 cm) higher than the front. Block the wheels.

8.Place the transmission in PARK. Lock the parking brake. Repeat steps 4 to 6 until no more particles are expelled.

9.Stop the engine. Allow the arrester to cool.

10.Reinstall the arrester plug and remove the exhaust outlet cover or plug.

125

Page 127
Image 127
Polaris 550 EPS owner manual Spark Arrester