FEATURES AND CONTROLS
Instrument Cluster
Diagnostic Display Code Definitions
Sportsman X2 550 EPS Diagnostic Codes
EPS Models Only
Steering Over Current Shut Down | Current Above Normal or | 520221 | 6 | |
| Grounded |
|
| |
Steering Excessive Current Error | Current Above Normal or | 520222 | 6 | |
| Grounded |
|
| |
Steering Torque Sensor T1 Partial | T1 Shorted to Ground | 520223 | 4 | |
Failure |
|
|
| |
T1 Shorted to Bus | 520223 | 3 | ||
| ||||
Steering Torque Sensor T2 Partial | T2 Shorted to Ground | 520224 | 4 | |
Failure |
|
|
| |
T2 Shorted to Bus | 520224 | 3 | ||
| ||||
Steering Torque Sensor Full Failure | T1 and T2 Shorted to Ground | 520225 | 4 | |
| T1 and T2 Shorted to Bus | 520225 | 3 | |
| T1 Shorted to Ground & T2 | 520225 | 16 | |
| Shorted to Bus |
|
| |
| T2 Shorted to Ground & T1 | 520225 | 17 | |
| Shorted to Bus |
|
| |
| T1 and T2 are Shorted | 520225 | 2 | |
Steering Position Sensor P1 Partial | P1 Shorted to Ground | 520226 | 4 | |
Failure |
|
|
| |
P1 Shorted to Bus | 520226 | 3 | ||
| ||||
Steering Position Sensor P2 Partial | P2 Shorted to Ground | 520227 | 4 | |
Failure |
|
|
| |
P2 Shorted to Bus | 520227 | 3 | ||
| ||||
Steering Position Sensor Full Failure | P1 and P2 Shorted to Ground | 520228 | 4 | |
| P1 and P2 Shorted to bus | 520228 | 3 | |
EPAS Inverter Temperature | Greater than 110 Degrees C | 520229 | 16 | |
| Greater than 120 Degrees C | 520229 | 0 | |
EPAS CAN Communications | No RX Message for 2 Seconds | 520230 | 9 | |
Receive Error |
|
|
| |
EPAS CAN Communications | No TX Message for 2 Seconds | 520231 | 9 | |
Transmit Error |
|
|
|
54