Polycom 3804-11530-222 manual Cfg Action Parameter Description File

Models: 3804-11530-222

1 68
Download 68 pages 12.81 Kb
Page 44
Image 44

 

Release Notes - SIP Application

Changes

 

 

 

 

 

 

 

.cfg

Action

Parameter

Description

 

File

 

 

 

 

 

sip

added

qos.ip.rtp.dscp

This parameter allows the DSCP of packets

 

 

 

 

 

to be specified. If set to a value this will

 

 

 

 

 

override the other qos.ip.rtp… parameters.

 

 

 

 

 

Default is Null which means the other

 

 

 

 

 

qos.ip.rtp… parameters will be used.

 

 

 

 

 

Possible values are 0 to 63, EF, AF11,

 

 

 

 

 

AF12, AF13, AF21, AF22, AF23, AF31,

 

 

 

 

 

AF32, AF33, AF41, AF42 or AF43.

 

 

sip

added

qos.ip.callControl.dscp

This parameter allows the DSCP of packets

 

 

 

 

 

to be specified. If set to a value this will

 

 

 

 

 

override the other qos.ip.callControl…

 

 

 

 

 

parameters. Default is Null which means the

 

 

 

 

 

other qos.ip.callControl… parameters will be

 

 

 

 

 

used.

 

 

 

 

 

Possible values are 0 to 63, EF, AF11,

 

 

 

 

 

AF12, AF13, AF21, AF22, AF23, AF31,

 

 

 

 

 

AF32, AF33, AF41, AF42 or AF43.

 

 

sip

added

pres.reg

Default = 1. Can be 1, 2, 3, …. Must be a

 

 

 

 

 

valid line/registration number. If the number

 

 

 

 

 

is not a valid line/registration number, it is

 

 

 

 

 

ignored.

 

 

 

 

 

Specifies the line/registration number used

 

 

 

 

 

to send SUBSCRIBE for presence.

 

 

sip

added

mb.idleDisplay.home

mb.idleDisplay.home can be empty or any

 

 

 

 

 

fully formed valid HTTP URL. Length up to

 

 

 

 

 

255 characters.

 

 

 

 

 

Default is empty.

 

 

 

 

 

This specifies the URL used for the

 

 

 

 

 

microBrowser idle display home page.

 

 

 

 

 

Example: http://www.example.com/

 

 

 

 

 

xhtml/frontpage.cgi?page=home.

 

 

 

 

 

If empty, there will be no micro Browser idle

 

 

 

 

 

display feature.

 

 

sip

added

mb.idleDisplay.refresh

Can be 0 or an integer greater than 5.

 

 

 

 

 

Values from 1 to 4 will be ignored, and 5 will

 

 

 

 

 

be used instead.

 

 

 

 

 

Default = 0

 

 

 

 

 

This specifies the period in seconds

 

 

 

 

 

between refreshes of the microBrowser idle

 

 

 

 

 

display content.

 

 

 

 

 

0 = the idle display microBrowser is not

 

 

 

 

 

refreshed.

 

 

 

 

 

Note: If an HTTP Refresh header is

 

 

 

 

 

detected, it will be respected, even if this

 

 

 

 

 

parameter is set to 0. The use of this

 

 

 

 

 

parameter in combination with the Refresh

 

 

 

 

 

HTTP header may cause the idle display to

 

 

 

 

 

refresh at unexpected times.

 

 

sip

removed

voIpProt.SIP.WM50

For selecting between Windows Messenger

 

 

 

 

 

4.7 and 5.0 (no longer supported).

 

Page 38

Copyright © 2007 Polycom, Inc.

Page 44
Image 44
Polycom 3804-11530-222 manual Cfg Action Parameter Description File