program shall prepare the terminal to standby for LAN Wake Up during power off so that when the predefined condition is met (LAN status change or receiving certain packet) the TP6000 will be powered on.
When the TP6000 system is turned off after a successful boot up, the defined preset power on functions will keep monitoring for the preset conditions. When a Modem call or LAN Wake Up Packet is received, the system will be turned on and start to work according to the security conditions as the application program defines if the Ring Power Up Control or LAN Wake Up function is enabled. If the Power Up by Alarm is enabled, the TP6000 system will be turned on at the defined time (Hour : Minute : Second) of the preset day of week, day of month, month of year or even every day if these items are not defined.
Please note that if the TP6000 system is improperly turned off before a complete boot up procedure, the above preset power on control functions will be disabled until next turning off after a complete boot up.
MAGNETIC STRIPE READER
The magnetic stripe reader, if installed, will be mounted on the right edge of the TP6000 series. When reading an ISO standard magnetic card, please face the magnetic stripe to the center of TP6000 series and slide the card downward through the slot.
CASH DRAWER(S)
The cash drawer control port, if connected with Posiflex cash drawer, provides not only a way to open the cash drawer through software commands but also a detection method for the software to check the drawer open status for consequent security measures.
The TP6000 series provide one cash drawer connector for control over two cash drawers. This unified CR connector, if connected with a standard cable CCBLA180 that is an accessory of the Posiflex cash drawer CR3100 or CR3200, controls one cash drawer. When an optional split cash drawer control cable CCBLA238 is used with this unified CR1 connector, this connector controls two cash drawers according to the software commands.
TP6000 USER’S MANUAL 5 - 5