SINGLE MODE

In single mode, the device performs automatic positioning of the table to the programmed target position. The “Table Up” or “Table Down” button on the planer should be pushed and held; when the table has fully adjusted to the target position, the table will automatically stop in position. Release the push button.

Setting Target Value

Step 1: Press

(Target window LED starts blinking)

Step 2: Enter the target value using numerical keypad.

Step 3: Press

to complete.

LED lamp starts blinking – the device is ready to start the positioning.

Start/Stop/Cancel

Press to start the positioning. The LED lamp now stops blinking and remains on during the procedure.

Press to cancel the positioning. The LED lamp is turned off.

If the key is pressed while the positioning is running, the procedure is

interrupted, the machine is stopped, and the

LED is turned off. To repeat the

positioning of the same target, press

.

To program another target value, press

- enter new value -

.

22

Page 22
Image 22
Powermatic WP2510 operating instructions Setting Target Value, Start/Stop/Cancel