Display

Possible cause: a. no sensor

b.9-pin connector is loose

c.wire broken

d.the gap between sensor and tape is too large

Excluding: Check the sensor, sensor cable and sensor connector.

Display

Possible cause: Incorrect operation.

Excluding: Press to clear.

Display

This message appears after power-on and indicates battery discharged. The C-type battery MUST be replaced to resume the operation of the device. Change as follows:

1.Open the planer’s top right side panel to access the rear of the Controller.

2.Turn the power off. Be careful not to move the table during power off. Replace the battery and turn the power on. The device will resume normal operation.

34

Page 34
Image 34
Powermatic WP2510 operating instructions Possible cause Incorrect operation Excluding Press to clear