4 – Installation

 

 

Installing a Switch

 

 

 

 

„To start SANsurfer Switch Manager as a standalone application, do the following.

1.Start the SANsurfer Switch Manager using one of the following methods:

‰For Windows, double-click the SANsurfer Switch Manager shortcut, or select SANsurfer Switch Manager from Start menu, depending on how you installed the SANsurfer Switch Manager application. From a command line, you can enter the SANsurferSwitchManager command:

<install_directory>SANsurferSwitchManager.exe

‰For Linux or Solaris, enter the SANsurferSwitchManager command:

<install_directory>SANsurferSwitchManager

‰To open the SANsurfer Switch Manager web applet, enter the switch IP address in an internet browser. If your workstation does not have the Java 2 Run Time Environment program, you will be prompted to download it.

2.In the Initial Start dialog, click the Open Configuration Wizard button. When you power up the switch, the Configuration Wizard will recognize the switch and lead you through the configuration process.

4.2.7

Connect the Switch to AC Power

WARNING!! This product is supplied with a 3-wire power cable and plug for the user’s safety. Use this power cable in conjunction with a properly grounded outlet to avoid electrical shock. An electrical outlet that is not correctly wired could place hazardous voltage on metal parts of the switch chassis. It is the responsibility of the customer to ensure that the outlet is correctly wired and grounded to prevent electrical shock.

You may require a different power cable in some countries because the plug on the cable supplied with the equipment will not fit your electrical outlet. In this case, you must supply your own power cable. The cable you use must meet the following requirements:

„For 125 Volt electrical service, the cable must be rated at 10 Amps and be approved by UL and CSA.

„For 250 Volt electrical service: The cable must be rated at 10 Amps, meet the requirements of H05VV-F, and be approved by VDE, SEMKO, and DEMKO.

59042-06 A

4-13

Page 61
Image 61
Q-Logic 2-8C manual Connect the Switch to AC Power

2-8C specifications

The Q-Logic 2-8C is a cutting-edge connectivity solution designed for enterprise environments that require robust performance and scalability in storage networking. This versatile product serves as a bridge between various storage devices and servers, ensuring seamless data transfer and high availability across complex IT infrastructures.

One of the standout features of the Q-Logic 2-8C is its advanced Fibre Channel technology. Supporting speeds of up to 32 Gbps, this adapter significantly enhances data transfer rates, allowing businesses to efficiently handle large volumes of information. The high bandwidth capability is particularly beneficial for data-intensive applications, including databases and virtualization environments, where speed and reliability are paramount.

The architecture of the Q-Logic 2-8C is built around a dual-port design, which promotes redundancy and load balancing. This means that even if one port encounters issues, the other can seamlessly take over, ensuring uninterrupted connectivity. Furthermore, the dual-port architecture provides the flexibility to connect to multiple storage arrays, maximizing resource utilization and minimizing downtime.

Another notable feature is the support for advanced management protocols and interoperability standards. The Q-Logic 2-8C is compatible with a wide array of operating systems and virtualization platforms, making it an ideal choice for heterogeneous environments. This broad compatibility ensures that organizations can integrate the adapter with their existing infrastructure without significant modifications, thus preserving their overall investment.

The Q-Logic 2-8C also incorporates sophisticated security features, such as end-to-end data encryption and access control mechanisms. These features are essential in today’s data-sensitive landscape, where organizations face increasing threats from cyberattacks. The added layer of security ensures that data remains protected during transit, giving businesses peace of mind.

In terms of energy efficiency, the Q-Logic 2-8C adheres to modern standards, consuming less power compared to its predecessors. This not only reduces operational costs but also aligns with sustainability initiatives that many organizations are pursuing.

With its powerful combination of speed, reliability, security, and energy efficiency, the Q-Logic 2-8C represents a robust solution for organizations looking to enhance their storage connectivity. Its advanced features cater to the demands of modern data centers, making it a strategic asset for businesses aiming to maintain a competitive edge in the ever-evolving digital landscape.