B – Command Line Interface

0

 

 

Show Command

 

 

 

 

 

 

 

 

 

Table B-15. Show Port Parameters (Continued)

 

 

 

 

 

 

 

Entry

Description

 

 

 

 

 

 

FBusy

Number of times the switch sent a F_BSY because Class 2

 

 

 

 

frame could not be delivered within ED_TOV time. Number

 

 

 

 

of class 2 and class 3 fabric busy (F_BSY) frames

 

 

 

 

generated by this port in response to incoming frames.

 

 

 

 

This usually indicates a busy condition on the fabric or

 

 

 

 

N_Port that is preventing delivery of this frame.

 

 

Flowerrors

Received a frame when there were no available credits.

 

 

FReject

Number of frames from devices that were rejected.

 

 

InvalidCRC

Invalid CRC detected.

 

 

InvalidDestAddr

Invalid destination address detected.

 

 

LIP_AL_PD_ALPS

Number of F7, AL_PS LIPs, or AL_PD (vendor specific)

 

 

 

 

resets, performed.

 

 

LIP_F7_AL_PS

This LIP is used to reinitialize the loop. An L_Port,

 

 

 

 

identified by AL_PS, may have noticed a performance

 

 

 

 

degradation and is trying to restore the loop.

 

 

LIP_F8_AL_PS

This LIP denotes a loop failure detected by the L_Port

 

 

 

 

identified by AL_PS.

 

 

LIP_F7_F7

A loop initialization primitive frame used to acquire a valid

 

 

 

 

AL_PA.

 

 

LIP_F8_F7

A loop initialization primitive frame used to indicate that a

 

 

 

 

loop failure has been detected at the receiver.

 

 

Link Failures

Number of optical link failures detected by this port. A link

 

 

 

 

failure is a loss of synchronization or a loss of signal while

 

 

 

 

not in the offline state. A loss of signal causes the switch to

 

 

 

 

attempt to re-establish the link. If the link is not

 

 

 

 

re-established, a link failure is counted. A link reset is

 

 

 

 

performed after a link failure.

 

 

Login

Number of device logins

 

 

Logout

Number of device logouts

 

 

LoopTimeouts

A two (2) second timeout as specified by FC-AL-2.

 

 

LossOfSync

Number of synchronization losses (>100 ms) detected by

 

 

 

 

this port. A loss of synchronization is detected by receipt of

 

 

 

 

an invalid transmission word.

 

 

PrimSeqErrors

Primitive sequence errors detected.

 

 

 

 

 

 

B-58

59042-06 A

Page 150
Image 150
Q-Logic 2-8C manual Lipalpdalps

2-8C specifications

The Q-Logic 2-8C is a cutting-edge connectivity solution designed for enterprise environments that require robust performance and scalability in storage networking. This versatile product serves as a bridge between various storage devices and servers, ensuring seamless data transfer and high availability across complex IT infrastructures.

One of the standout features of the Q-Logic 2-8C is its advanced Fibre Channel technology. Supporting speeds of up to 32 Gbps, this adapter significantly enhances data transfer rates, allowing businesses to efficiently handle large volumes of information. The high bandwidth capability is particularly beneficial for data-intensive applications, including databases and virtualization environments, where speed and reliability are paramount.

The architecture of the Q-Logic 2-8C is built around a dual-port design, which promotes redundancy and load balancing. This means that even if one port encounters issues, the other can seamlessly take over, ensuring uninterrupted connectivity. Furthermore, the dual-port architecture provides the flexibility to connect to multiple storage arrays, maximizing resource utilization and minimizing downtime.

Another notable feature is the support for advanced management protocols and interoperability standards. The Q-Logic 2-8C is compatible with a wide array of operating systems and virtualization platforms, making it an ideal choice for heterogeneous environments. This broad compatibility ensures that organizations can integrate the adapter with their existing infrastructure without significant modifications, thus preserving their overall investment.

The Q-Logic 2-8C also incorporates sophisticated security features, such as end-to-end data encryption and access control mechanisms. These features are essential in today’s data-sensitive landscape, where organizations face increasing threats from cyberattacks. The added layer of security ensures that data remains protected during transit, giving businesses peace of mind.

In terms of energy efficiency, the Q-Logic 2-8C adheres to modern standards, consuming less power compared to its predecessors. This not only reduces operational costs but also aligns with sustainability initiatives that many organizations are pursuing.

With its powerful combination of speed, reliability, security, and energy efficiency, the Q-Logic 2-8C represents a robust solution for organizations looking to enhance their storage connectivity. Its advanced features cater to the demands of modern data centers, making it a strategic asset for businesses aiming to maintain a competitive edge in the ever-evolving digital landscape.