4–Diagnostics/Troubleshooting
Transceiver Diagnostics
59265-02 B 4-11
2. Reset the port, and then perform an external port loopback test to validate
the port and the SFP. For information about testing ports, refer to the QLogic
5800V Series Fibre Channel Switch Command Line Interface Guide or the
QLogic 5800V Series QuickTools Switch Management User’s Guide. Does
the port pass the test?
Yes—Continue.
No—Replace the SFP and repeat the test. If the port does not pass the
test, contact your authorized maintenance provider. Otherwise
continue.
3. Replace the Fibre Channel port cable. Is the problem corrected?
Yes— Com ple te.
No—Continue.
4. Inspect the device to which the affected port is connected, and confirm that
the device and its adapter are working properly. Make repairs and
corrections as needed. If the condition remains, contact your authorized
maintenance provider.
Transceiver Diagnostics
You can display the following transceiver information using the Show Media CLI
command:
Port number
Manufacturer
Temperature (°C)
Operating voltage (Volts)
Transmitter bias (Milliamps)
Transmitter power (Milliwatts)
Receiver power (Milliwatts)
The display indicates warning and alarm conditions for both high and low values.