2100 Millennium Wood Stove (ACC)
R
| Chimney Requirements |
|
Venting Components | B. Chimney Systems | |
A.5 |
|
Chimney Connector: | Prefabricated Metal Chimney |
|
It is also known as flue pipe or stove pipe. The chimney connector joins the stove to the chimney. It must be a 6 inch (152mm) minimum diameter 24 gauge mild steel black or 26 gauge blued steel, or an approved
Thimble:
A manufactured or
Chimney:
The chimney can be new or existing, masonry or prefabricated and must meet the following minimum requirements specified in Section 5B.
Listed Termination Cap
Roof Brace (if required)
Storm Collar
Flashing
Trim Collar on | Listed Chimney | |
Inside Wall | Insulated " T " | |
| ||
Chimney | Wall Support | |
Connector | ||
| ||
| Thimble | |
Floor |
| |
Protector |
|
•Must be minimum 6 inch (152mm) diameter (ID) high temperature chimney listed to UL 103 HT (2100oF) or ULC S629M.
•Must use components required by the manufacturer for installation.
•Must maintain clearances required by the manufacturer for installation.
•Refer to manufacturers instructions for installation.
NOTE: In Canada when using a
FACTORY-BUILT CHIMNEYS.
Listed Termination Cap
Storm Collar
Flashing
Listed Chimney
Ceiling Support
Chimney
Connector
Floor
Protector
Figure 14.1 Prefabricated Exterior Chimney | Figure 14.2 - Prefabricated Interior Chimney |
Page 14 |
| May 5, 2011 |