2100 Millennium Wood Stove (ACC)
R
B. Outside Air Kit Installation
A source of air (oxygen) is necessary in order for combus- tion to take place. Whatever combustion air is consumed by the fire must be replaced. Air is replaced via air leakage around windows and under doors. In homes that have tightly sealed doors and windows, an outside air source is needed. An optional Outside Air Kit is available.
Included in
Included in
Items Needed for Installation (not supplied)
•4 inch flex aluminum pipe, or if using alternate material, then it shall be made from durable,
•Phillips head screw driver
•Silicone sealant
•Drills and saws necessary for cutting holes through the wall or flooring in your home
WARNING
Fire Risk.
Asphyxiation Risk.
Do not draw outside combustion air from:
•Wall, floor or ceiling cavity
•Enclosed space such as an attic or garage
•Close proximity to exhaust vents or chimneys Fumes or odor may result
WARNING
Asphyxiation Risk.
Outside air inlet must be located to prevent blockage from:
•Leaves
•Snow or ice
•Other debris
Block may cause combustion air starvation
Smoke spillage may set off alarms or irritate sensitive individuals.
1. | Remove all materials from packing box. |
| WARNING | |
|
|
| ||
2. | Using a #2 Phillips screw driver attach the flex adapter to |
| Asphyxiation Risk. | |
| Length of outside air supply duct shall NOT exceed | |||
| the stove using 4 screws. Figure 12.1. |
| ||
3. | For floor installations, remove circular |
| the length of the vertical height of the exhaust flue. | |
| • Fire will not burn properly | |||
| base of the pedestal. Figure 12.1. |
| ||
|
| • Smoke spillage occurs when door is opened due to | ||
|
|
| ||
4. | Floor & Rear Installation: Cut a 4 inch (102mm) hole in |
| air starvation. | |
| outside wall or floor to accommodate outside air piping. | 5. Floor Installation Alternative: In some instances you | ||
| Use 4 inch (102mm) aluminum metal flex or rigid piping | |||
| to directly connect outside air to appliance intake. Use |
| may not be able to install the flex pipe as show in Figure | |
| the supplied termination cap with a rodent screen. Seal |
| 12.1. If that is the case, you will need to order SRV7033- | |
| between the wall (or floor) and the pipe with silicone to |
| 041 which includes a cover plate and sealing rope as | |
| prevent moisture penetration. |
| shown in Figure 12.2. The goal is to seal the pedestal | |
|
|
| so no room air can leak into the pedestal and to seal or |
for cold air infiltration.
For Floor Installa- tions Remove Circular
Flex Adapter
Wire Tie
Termination
Cap
Flex Line Wire Tie
Cover Plate
Figure 12.1 - Floor & Rear Installation | Figure 12.2 - Floor Installation Alternative |
Page 12 |
| May 5, 2011 |