2100 Millennium Wood Stove (ACC) |
| R | ||
|
| |||
|
| Mobile Home Installation |
|
|
| must use a |
|
| |
You6 |
|
|
| |
| Spark Arestor Cap | |||
|
| |||
|
| |||
1. | An outside air inlet must be provided for combustion See |
|
| |
| page 12 for installation information. | Storm Collar |
| |
2. | Appliance must be secured to the mobile home structure |
| Roof Flashing | |
| by bolting the pedestal through hearth pad and into |
| ||
|
|
| ||
| floor. |
|
|
|
3. | Appliance must be grounded with #8 solid copper |
|
| |
| grounding wire or equivalent and terminated at each end | Joist Shield/Firestop |
| |
| with N.E.C. approved grounding device. | Double wall | ||
|
|
|
| |
4. | Appliance must be installed with an approved UL103 HT |
| connector pipe | |
| ventilated chimney connector, UL103 HT chimney, and |
|
| |
| terminal cap with spark arrestor. Never use a single wall |
|
| |
| connector (stove pipe) in a mobile home installation. Use |
|
| |
| only |
|
| |
| metalbestos DS or Security DL |
|
| |
| any listed |
|
| |
5. | In Canada, this appliance must be connected to a 6 inch |
| Outside Air | |
| (152mm) |
| ||
| 629M, STANDARD FOR FACTORY BUILT CHIMNEYS. |
| Rear Vent | |
|
|
| ||
6. | Follow the chimney and chimney connector manufacturer’s | Floor Protector |
| |
| instructions when installing the flue system for use in a |
| ||
| mobile home. |
|
| |
7. | Maintain clearance to combustibles. |
|
| |
8. | Floor protection requirements must be followed | Outside Air Floor Vent |
| |
| precisely. |
| ||
9. | Use silicone to create an effective vapor barrier at the | Figure 18.1 |
| |
| location where the chimney or other component penetrates |
| ||
| to the exterior of the structure. |
|
|
NOTE: Offsets from the vertical, not exceeding 45°, are | CAUTION |
| |
allowed per Section 905(a) of the Uniform Mechanical Code | THE STRUCTURAL INTEGRITY OF THE MOBILE HOME | ||
(UMC). Offsets greater than 45° are considered horizontal | |||
FLOOR, WALL AND CEILING/ROOF MUST BE MAIN- | |||
and are also allowed, providing the horizontal run does not | |||
TAINED | |||
exceed 75% of the vertical height of the vent. Construction, | |||
Do NOT cut through: | |||
clearance and termination must be in compliance with the | |||
• Floor joist, wall, studs or ceiling trusses. | |||
UMC Table 9C. This installation must also comply with NFPA | |||
• Any supporting material that would affect the structural | |||
211. | |||
integrity. | |||
NOTE: Top sections of chimney must be removable to allow | |||
|
| ||
|
| ||
maximum clearance of 13.5 feet (411cm) from ground level |
|
| |
for transportation purposes. |
|
| |
|
|
10. | Burn wood only. Other types of fuels may generate | WARNING | |
| poisonous gases (e.g., carbon monoxide). | Asphyxiation Risk. | |
11. | If unit burns poorly while an exhaust blower is on in | ||
NEVER INSTALL IN A SLEEPING ROOM. | |||
| home, (i.e., range hood), increase combustion air. | ||
| Consumes oxygen in the room. | ||
|
|
12.Installation shall be in accordance with the Manufacturers Home & Safety Standard (HUD) CFR 3280, Part 24.