C. Equivalent Feet of Pipe

CB 1200 Pellet Stove

R

C. Equivalent Feet of Pipe

The table below can help you calculate the equivalent feet of pipe which is a method used to determine pellet vent size.

Figure 12.1.

D. Pipe Selection Chart WARNING

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appli- ance. For assistance or additional information consult a qualified installer, service agency or your dealer.

Example of 3 Elbow-Rear Vent Termination Calculaton

 

2 ft (609mm)

Pellet Venting

# of

Feet of

Multipled

Equivalent

Components

 

Component

Elbows

Pipe

By

Feet

Equivalent Feet

 

 

 

 

90o Elbow or Tee

3

 

X

5

15

 

 

45o Elbow

 

 

X

3

 

3 ft

 

Horizontal Pipe

 

7

X

1

7

(914mm)

 

Vertical Pipe

 

2

X

0.5

1

2 ft (609mm)

Manual backgroundManual background 2 ft (609mm)

Total Equivalent Feet

23

Note: This is a generic example and is not intended to represent any specific fuel type.

Figure 12.1

 

 

 

 

 

 

 

 

 

 

 

D. Pipe Selection Chart

 

 

 

 

 

 

 

 

 

 

 

The chart will help you in determining proper

 

30

 

4 in. (102mm) Diameter Pipe Only

 

 

 

 

 

venting size according to the equivalent feet of

Example 1

 

 

 

 

 

 

 

 

 

 

pipe calculated above and the altitude above sea

 

20

 

 

 

 

 

 

 

 

 

level of this installation. Figure 12.2.

 

 

 

 

 

 

 

 

 

 

Equivalent Pipe

 

 

 

 

 

 

 

 

 

Locate the calculated equivalent feet of pipe on

Length In Feet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the vertical left side of the chart. Move to the

Example 2

10

 

 

 

 

 

 

 

 

 

right horizontally on the chart until you reach

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

your altitude above sea level.

 

 

 

 

 

 

 

 

 

 

 

If you fall below the diagonal line, 3 or 4 inch (76

 

3 in. or 4 in. (76mm or 102mm) Diameter Pipe

 

 

to 102mm) pipe may be used. If it is anywhere

 

0

2

3

4

5

6

7

8

9

10

above the diagonal line, a 4 inch (102mm) diam-

 

1

 

 

ALTITUDE IN THOUSANDS OF FEET

 

eter pipe is required.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The chart reveals that a 90° elbow is 5 times as

Figure 12.2

Example 1: If the equivalent length of pipe is 23 feet

restrictive to the flow of exhaust gases under

 

(7m)with altitude of 8,000 feet (2438m) you must use

positive pressure as 1 foot of horizontal pipe, and

 

 

4 inch (102mm) diameter type “L” or “PL” vent.

a foot of horizontal pipe is twice as restrictive as

 

 

Example 2: If the equivalent length of pipe is 12 feet

a foot of vertical pipe.

 

 

 

(3.7m) with altitude of 6,000 feet (1829m) you may

WARNING

 

use 3 or 4 inch (76 to 102mm) diameter type “L” or

 

“PL” vent

 

 

 

 

 

 

 

 

Fire Risk.

 

 

 

 

 

 

 

 

 

 

 

Do NOT pack insulation or other combustibles between firestops.

ALWAYS maintain specified clearances around venting and firestop systems.

Install firestops as specified.

Failure to keep insulation or other material away from vent pipe may cause fire.