B. Through The Wall
Horizontal termination cap must be a minimum of 12 inches. (305mm) from the wall. Approved for mobile home instal- lations. Must use 3 or 4 inch
NOTE:
In Canada, where passage through a wall or partition of combustible construction is desired, the installation shall conform to
NOTICE:
Please note that while the minimum clearance for the termination cap is 6 inches (152mm) there is the possibly of soot buildup around the termina- tion area. If this occurs we suggest to move the termination further away from the house to prevent it.
Straight Out | 2 in. |
| |
| (51mm) |
| |
| Minimum |
| |
6 in. |
|
| |
(152mm) |
|
| |
Minimum |
| Horizontal | |
From Glass |
| ||
Wall | Termination | ||
| |||
| Thimble | Cap | |
| 6 in. |
| |
| (152mm) |
| |
| Minimum |
| |
|
|
Figure 14.1
45 Degree
Illustration shows venting going in both directions. Choose which one is best for your installation.
6 in. (152mm)
Minimum
Wall
Thimble
6in.
(152mm) Minimum
2 in. (51mm)
Minimum
2 in. (51mm)
Minimum
Figure 14.2
Page 14 | December 16, 2011 |