Quadra-Fire CB1200M-MBK owner manual C. Hearth Pad Requirements UL and ULC, CB 1200 Pellet Stove

Models: CB1200M-MBK

1 48
Download 48 pages 22.84 Kb
Page 10
Image 10
C. Hearth Pad Requirements (UL and ULC)

CB 1200 Pellet Stove

C. Hearth Pad Requirements (UL and ULC)

Use a non-combustible floor protector, extending beneath appliance and to the front, sides and rear as indicated. Measure front distance “M” from the surface of the glass door.

 

L*

K

K

 

M

Figure 10.1

 

Hearth Pad Requirements

Inches

Millimeters

K

Sides

2

51

L*

Back

2

51

M

Front

6

152

*L Exception for Horizontal Installations:

USA INSTALLATIONS: A non-combustible floor protec- tion is recommended extending beneath the flue pipe when installed with horizontal venting or under the top vent adapter with vertical installation.

CANADA INSTALLATIONS: A non-combustible floor protection extending beneath the flue pipe is required with horizontal venting or under the top vent adapter with vertical installation.

R

Must extend 2 inches (51mm) beyond each

side of pipe (shaded area)

Figure 10.2

Page 10

7014-179D

December 16, 2011

Page 10
Image 10
Quadra-Fire CB1200M-MBK C. Hearth Pad Requirements UL and ULC, CB 1200 Pellet Stove, Must extend 2 inches 51mm beyond each