Setting Flame Height/manifold pressure

Setting Flame Height/manifold pressure

(To be done by a qualified service technician). Upon initial power-up of this device, valve pressure must be set for flame adjustment.

Loosen output pressure tap on valve and connect with pressure manometer.

Press flame button once (Fig. 10.4); fireplace will light with flames on high.

Turn solenoid clockwise to increase pressure, counterclockwise to decrease pressure until manifold pressure on high is 3.5” water column for natural gas (NG), 10.0” water column for propane (LP).

Once pressure is achieved spin jam-nut on solenoid stem tight against regulator face to prevent rotation. Do not overtighten.

Press flame button twice to turn fireplace off.

Remove manometer tube and tighten or close pressure tap. Use a soap solution to carefully check the pressure tap for leaks.

Wall Switch Button Operation

See Figure 10.4.

Wall Switch Button Operation Flame Button

Button Press: Unit On / Flames High, Turns on auxiliary power

Button Press: Flames Low

Button Press: Unit Off / Flames Off, Turns off auxiliary power

 Flame Button Fan / Blower Button Fan / Blower Button

Button Press: Fan High (“3”)

Button Press: Fan Medium (“2”)

Button Press: Fan Low (“1”)

Button Press: Fan Off

Temperature Button

Button Press will toggle between Automatic and Manual Operation

Press and Hold the button for 3 seconds to toggle between Fahrenheit and Centigrade Temperature Display.

Automatic Operation: Controller will monitor temperature and control unit according to the set point.

Manual Operation: Controller will not automatically change settings.

SET Set Temperature Button

Button Press: Displays Set Point

Use Up and Down Arrows to Adjust Set Point

Press Set Button to Store New Set Point

Temperature Set Point can be adjusted between the ranges of: 45-900Fahrenheit or 7-320Centigrade

NOTE: The controller will turn off the fireplace at 20 F over set point and turn it back on at 20 F below set point.

<>

Up and Down Arrows

 

Push to adjust set point temperature under automatic control.

AUX Auxiliary Button

Button Press: Turns on auxiliary power

Button Press: Turns off auxiliary power

Can be operated independently of all functions.

Child Proof Mode

To Enter Child Proof Mode:

Press the Up Arrow Button twice and Down Arrow Button once. The unit will send out 3 beeps and an indicator in the LCD panel will show that the child proof is on.

To Leave Child Proof Mode:

Press the Up Arrow Button twice and Down Arrow Button once. The unit will send out 3 beeps and the indicator in the LCD panel that shows that the child proof is on will disappear.

NOTE: When in Child Proof Mode, only the arrow buttons will have functionality. Unit can enter Child Proof when the fireplace is on or off.

INTELLIFIRE (IPI) MODELS ONLY

Temperature Button Cold Climate Button

Button Press: Turns on Climate Control

Button Press: Turns off Climate Control

This allows the pilot flame to stay lit when activated, a benefit of this is reduced condensation on the glass at start-up in colder climate conditions.

Operation Under Battery Power

A switch on the control box allows for battery power under no-power conditions. See Figure 10.6. By controlling the power supply with this switch, the batteries are supplying power only when needed, thus extending battery life. The switch also provides a convenient means for switching to battery power should there be a loss of 110 VAC power to the control box.

In the event of a power failure, switch the battery operation switch to the “Battery ON” position.

The fireplace can now be turned on and off with the ON/ OFF rocker switch located near the gas valve.

The wall switch functions will not operate under battery power.

Under battery control the only available function is flame “On” and “Off” in the high position.

To maximize battery life, and to restore full function capability of the wall switch, flip switch to “OFF” position

after 120 VAC power is restored.