Quadra-Fire QV36A-FB owner manual Getting Started, A. Design and Installation Considerations

Models: QV36A-FB

1 59
Download 59 pages 13.27 Kb
Page 6
Image 6
2 Getting Started

2 Getting Started

A. Design and Installation Considerations

Quadra-Fire direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is required.

CAUTION

Check building codes prior to installation.

Installation MUST comply with local, regional, state and national codes and regulations.

Consult local building, fire officials or authorities having jurisdic- tion about restrictions, installation inspection, and permits.

When planning an appliance installation, it’s necessary to determine the following information before installing:

Where the appliance is to be installed.

The vent system configuration to be used.

Gas supply piping.

Electrical wiring.

Framing and finishing details.

Whether optional accessories—devices such as a fan, wall switch, or remote control—are desired.

A. Design and Installation Considerations WARNING

Keep appliance dry.

• Mold or rust may cause odors.

• Water may damage controls.

B. Tools and Supplies Needed

Before beginning the installation be sure that the following tools and building supplies are available.

Reciprocating saw

Framing material

Pliers

Noncorrosive leak check solution

Hammer

Gloves

Phillips screwdriver

Framing square

Flat blade screwdriver

Electric drill and bits (1/4 in.)

Plumb line

Safety glasses

Level

Tape measure

Manometer

Voltmeter

1/2 - 3/4 inch length, #6 or #8 Self-drilling screws

Caulking material (300ºF minimum continuous exposure rating)

C. Inspect Appliance and Components

B. Tools and Supplies Needed WARNING

Inspect appliance and components for damage.

Damaged parts may impair safe operation.

Do NOT install damaged components.

Do NOT install incomplete components.

Do NOT install substitute components. Report damaged parts to dealer.

Carefully remove the appliance and components from the packaging.

The vent system components and trim doors are shipped in separate packages.

The gas logs may be packaged separately and must be field installed.

Report to your dealer any parts damaged in shipment, particularly the condition of the glass.

Read all of the instructions before starting the insta- llation. Follow these instructions carefully during the installation to ensure maximum safety and benefit.

C. Inspect Appliance and Components WARNING

Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:

Installation and use of any damaged appliance or vent system component.

Modification of the appliance or vent system.

Installation other than as instructed by Hearth & Home Technologies.

Improper positioning of the gas logs or the glass door.

Installation and/or use of any component part not approved by Hearth & Home Technologies.

Any such action may cause a fire hazard.

6

Quadra-Fire • Expression 36 (QV36A-FB)2062-900 Rev. S • 11/11

Page 6
Image 6
Quadra-Fire QV36A-FB owner manual Getting Started, A. Design and Installation Considerations, B. Tools and Supplies Needed