THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE.

This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the chimney. The fl ue length must be a minimum length of 8' (2.44m) and a maximum of 35' (10.7m). Periodically check that the vent is unrestricted.

Masonry chimneys may take various contours which the fl exible liner will accommodate. However, keep the flexible liner as straight as possible, avoid unnecessary bending.

INSTALLATION WITH 3" & 3" LINERS

Part #
Description

 

 

948-305

3" Flex - 35 ft. (intake & exhaust)

946-529

FPI Co-linear DV Vertical Termination Cap & Flashing

 

 

 

 

 

 

 

Vent Run

Vent Restrictor

Burner Aeration

 

Position

Setting

 

 

 

 

 

 

 

 

 

 

 

8' to 20'

1"

3/16"

 

 

 

 

 

 

 

 

 

20' to 35'

3/4"

3/16"

 

 

 

 

 

 

 

NOTE: See instructions in the "Vent Restrictor Positon" section on positioning of the vent restrictor.

The L234 is also approved for use with a 2" liner for air intake and a 3" liner for exhaust. This would be suitable for a Class A wood burning chimney with a minimum 6" round fl ue.

The chimney must be lined with one 2" diameter liner for intake and one 3" diameter liner for exhaust. The minimum vent length is 8' and maximum is 35'.

INSTALLATION WITH 3" & 2" LINERS

Part #

Description

948-305

3" Flex - 35 ft. (exhaust)

948-316

2" Flex - 35 ft. (intake)

946-582

FPI Co-linear DV Vertical Termination Cap, Flashing &

 

2" Collar

Vent Run
Vent Restrictor
Burner Aeration

Position

Setting

 

 

 

 

8' to 20'

1"

3/16"

 

 

 

20' to 35'

1"

1/8"

 

 

 

NOTE: See instructions in the "Vent Restrictor Positon" section on positioning of the vent restrictor.

Alternative Approved Venting Components*

980

Vertical Termination Cap

991

High Wind Cap

923GK

3" Co-linear Adaptor with fl ashing

In areas of consistently high winds, we recommend using the Simpson Dura-Vent System (923GK adapter and 991 high-wind cap).

The Air Intake pipe must be attached to the inlet air collar of the termination cap.

*NOTE: Simpson Duravent can only be used with 3" and 3" liners.