INSTALLATION
VENTING
INSTALLATION
THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE.
This appliance is designed to be attached to two 3" (76mm)
Masonry chimneys may take various contours which the fl exible liner will accommodate. However, keep the flexible liner as straight as possible, avoid unnecessary bending.
INSTALLATION WITH 3" & 3" LINERS
Part # | Description |
|
| ||
3" Flex - 35 ft. (intake & exhaust) | |||||
FPI | |||||
|
|
|
|
|
|
| Vent Run | Vent Restrictor | Burner Aeration | ||
| Position | Setting | |||
|
|
| |||
|
|
|
|
|
|
|
| 8' to 20' | 1" | 3/16" |
|
|
|
|
|
|
|
|
| 20' to 35' | 3/4" | 3/16" |
|
|
|
|
|
|
|
NOTE: See instructions in the "Vent Restrictor Positon" section on positioning of the vent restrictor.
The L234 is also approved for use with a 2" liner for air intake and a 3" liner for exhaust. This would be suitable for a Class A wood burning chimney with a minimum 6" round fl ue.
The chimney must be lined with one 2" diameter liner for intake and one 3" diameter liner for exhaust. The minimum vent length is 8' and maximum is 35'.
INSTALLATION WITH 3" & 2" LINERS
Part # | Description |
3" Flex - 35 ft. (exhaust) | |
2" Flex - 35 ft. (intake) | |
FPI | |
| 2" Collar |
Vent Run | Vent Restrictor | Burner Aeration | |
Position | Setting | ||
| |||
|
|
| |
8' to 20' | 1" | 3/16" | |
|
|
| |
20' to 35' | 1" | 1/8" | |
|
|
|
NOTE: See instructions in the "Vent Restrictor Positon" section on positioning of the vent restrictor.
Alternative Approved Venting Components*
980 | Vertical Termination Cap |
991 | High Wind Cap |
923GK | 3" |
In areas of consistently high winds, we recommend using the Simpson
The Air Intake pipe must be attached to the inlet air collar of the termination cap.
*NOTE: Simpson Duravent can only be used with 3" and 3" liners.
10 | Regency® L234 Direct Vent Gas Insert |