![Do not overtighten the screw. Recommended to](/images/new-backgrounds/44579/4457929x1.webp)
INSTALLATION
9) Remove burner orifice with a 1/2" wrench | 13) From the valve remove the black protec- |
and discard. | tion cap by hand from the |
| (Fig.1). |
WARNING!
Do not overtighten the screw. Recommended togrip the wrench by the short side.18)Verify that if the conversion is from NG to LPG, the screw must be
INSTALLATION
Fig. 1
Red
LPG Configuration
10)Install the new LP burner orifice stamped #54 and tighten.
11)Pull off the pilot cap to expose the pilot orifice.
14)Insert the allen key into the hexagonal
Fig.2
19)
12)Unscrew the pilot orifice with the supplied allen key and replace it with the LP pilot orifice in the kit and
15)Check that the screw is clean and if necessary remove dirt.
16)Flip the screw (Fig. 3).
Fig.3
17)Using the allen key as shown in Fig.4, rotate the screw clockwise until snug, do not overtighten.
Fig.4
Fig. 6
WARNING!
Also check that the pilot and mainburner injectorsare appropriate for the gas type.
20)Attach the label "This unit has been con- verted to Propane" near or on top of the serial # decal.
21)Replace yellow "Natural Gas" label with red "LPG" label.
22)Reverse steps 8) to 1).
NOTE: Before
23)Check the inlet and outlet pressures.
24)Check operation of flame control.
25)Check for proper flame appearance.
Regency® L234 Direct Vent Gas Insert | 15 |