VALVE REPLACEMENT

MAINTENANCE

VALVE REPLACEMENT

1)Open the left and right side faceplate panels.

2)Remove the bottom louver by pulling out.

3)Remove the glass door.

a)Pull off the left side spring hook that holds the door in place. While holding the hook turn it upside down and place it into the middle opening on the top side mounting bracket. Repeat for right side.

Spring Hook

MAINTENANCE

b) Swing the door out 45 degrees and lift up 7)

Disconnect the gas connection to the

and out.

valve.

8)

Disconnect the ignitor wire from the DC

 

Sparker.

9)

Disconnect the valve wires from the DC

 

Sparker.

 

DC Sparker Wires

4)Remove the logs.

5)Remove brick panels, if installed.

6)Remove the valve shield by undoing the 2 screws.

10) Unplug the 2 connectors from the valve.

Top Mounting Bracket

Valve Shield

 

34

Regency® L234 Direct Vent Gas Insert

Page 34
Image 34
Regency L234-LP, L234-NG Maintenance, Valve Replacement, Spring Hook, DC Sparker Wires, Top Mounting Bracket