MAINTENANCE
VALVE REPLACEMENT
1)Open the left and right side faceplate panels.
2)Remove the bottom louver by pulling out.
3)Remove the glass door.
a)Pull off the left side spring hook that holds the door in place. While holding the hook turn it upside down and place it into the middle opening on the top side mounting bracket. Repeat for right side.
Spring Hook
MAINTENANCE
b) Swing the door out 45 degrees and lift up 7) | Disconnect the gas connection to the |
and out. | valve. |
8) | Disconnect the ignitor wire from the DC |
| Sparker. |
9) | Disconnect the valve wires from the DC |
| Sparker. |
| DC Sparker Wires |
4)Remove the logs.
5)Remove brick panels, if installed.
6)Remove the valve shield by undoing the 2 screws.
10) Unplug the 2 connectors from the valve.
Top Mounting Bracket | Valve Shield |
|
34 | Regency® L234 Direct Vent Gas Insert |