Regency P131, P121RC Installation, Venting Arrangements - Horizontal Terminations, Option

Models: P121LC P121 P121RC P131

1 40
Download 40 pages 33.79 Kb
Page 15
Image 15
VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS
Simpson Dura-Vent 4" inner diameter
6-5/8" outer diameter

INSTALLATION

VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS

SIMPSON DURA-VENT DIRECT VENT GS SYSTEM (Propane & Natural Gas)

The diagram below shows examples of horizontal termination arrangements using one, two, or three 90o elbows (two 45o elbows equal one 90o elbow).

Note:

1) A maximum of three 90o elbows are permitted.

2) Minimum distance between elbows is 1 ft. (305mm).

• Maintain clearances to combustibles as listed on page 9.

Horizontal vent must be supported every 3 feet.

Firestops are required at each floor level and whenever passing through a wall.

Must use optional flue adapter (Part# 510-994) when using Simpson Dura-Vent pipe.

A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.

Straight Out Horizontal Venting

Horizontal Venting with One (1) 90o Elbow

 

Option

V

H

 

A)

1' (305mm) Minimum

3' (914mm) Maximum

 

B)

2' (610mm) Minimum

6' (1.86m) Maximum

 

C)

3' (914mm) Minimum

9' (2.7m) Maximum

 

D)

4' (1.22m) Minimum

12' (3.6m) Maximum

 

E)

5' (1.5m) Minimum

15' (4.5m) Maximum

 

F)

6' (1.86m) Minimum

17' (5.1m) Maximum

 

With the above options, maximum total pipe length if 37 feet with

 

minimum of 6 feet total vertical and maximum 17 feet total horizontal.

 

Please note minimum 1 foot between 90o elbows is required.

Diagram 1

Diagram 2

Please note the minimum centerline for basic install shown above.

Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace