Regency P131, P121RC Maintenance, Glass Gasket, Removing Valve, Log Replacement, Door Glass

Models: P121LC P121 P121RC P131

1 40
Download 40 pages 33.79 Kb
Page 31
Image 31
MAINTENANCE

MAINTENANCE

2)

Remove the Cap, and shine a flashlight

 

down the Vent. Remove any bird nests, or

 

other foreign material.

3)

Check for evidences of excessive con-

 

densation, such as water droplets forming

 

in the inner liner, and subsequently dripping

 

out the joints, Continuous condensation

GLASS GASKET

REMOVING VALVE

If the glass gasket requires replacement use 1)

Shut off the gas supply.

a tadpole glass gasket (Part # 936-155).

 

2)

Remove the louvers and trim kit. Remove the

 

 

front door.

 

 

can cause corrosion of caps, pipe, and

fittings. It may be caused by having exces-

sive lateral runs, too many elbows, and

exterior portions of the system being ex-

posed to cold weather.

4) Inspect joints, to verify that no pipe sections

or fittings have been disturbed, and conse-

quently loosened. Also check mechanical

supports such as Wall Straps, or plumbers'

tape for rigidity.

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door and carefully remove the logs. (The pilot light generates enough heat to burn someone.) If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagrams under Log Installation.

DOOR GLASS

Your Regency fireplace is supplied with high temperature 5mm-Tempered glass & 5mm-Ce- ramic glass. If your glass requires cleaning, we recommend using an approved glass cleaner available at all authorized dealers. Do not use abrasive materials.

CAUTION&WARNINGS:

*Do not clean when the glass is hot.

*The use of substitute glass will void all product warranties.

*Care must be taken to avoid breakage of the glass.

*Do not strike or abuse the glass.

*Do not operate this fireplace without the glass front or with a cracked or broken glass front.

*Wear gloves when removing damaged or broken glass.

*Replacement of the glass panels should be done by a licensed or qualified service per son.

3)Remove the logs, embers.

4)Remove the grate by lifting straight up.

5)Remove the side brick clip in the top of the firebox and then slide the Side Brick Panel out. The brick panels are very fragile - handle with care.

Note: Improper positioning of logs may create carbon build-up and will severely alter the unit's perform- ance which is not covered under warranty.

THERMOPILE/

THERMOCOUPLE

1)

Open the Bottom Louvers or Grills. Remove

 

the Top Louver or Grill.

2)

Remove the Trim Kit, Glass Door, Log Set,

 

Grate and Burner Assembly (see page 26).

GLASSREPLACEMENT

In the event that you break your glass by impact, purchase your replacement from an authorized Regency dealer only. Replacement glass is shipped already installed into the door frame. Reinstall as per Glass Door Installation on page 22.

REPLACEMENTPARTS:

Front Door - Tempered (Part# 360-528)

Side Door - Tempered (Part# 360-529)

Front Door - Ceramic (Part# 360-538)

Side Door - Ceramic (Part# 360-539)

6)Remove the burner by removing the 4 screws.

3)

Disconnect thermocouple by loosening nut

 

from the valve with a 9mm wrench. Discon-

 

nect thermopile by loosening 2 screws

 

marked TP on the valve.

4)

Remove 2 screws from the pilot assembly

 

and pull up far enough to be able to loosen

 

the thermocouple or thermopile with a 7/16"

 

wrench. NOTE: the pilot line is very fragile,

 

use caution when pulling it up.

5)

Drop the thermocouple or thermopile down

 

through the extrusion and pull it out of the

 

unit.

6)

Reinstall the new ones in reverse order.

GOLD-PLATED

ACCESSORIES

The 24 carat gold-plated finish requires little maintenance, and need only be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the finish and void the warranty. Clean any finger- prints off before turning the unit on.

7)Slide the burner assembly away from the orifice and lift out.

Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace

31

Page 31
Image 31
Regency P131, P121RC Maintenance, Glass Gasket, Removing Valve, Log Replacement, Door Glass, Thermopile Thermocouple