Regency P121 Installation, Horizontal Venting with Two 2 90o Elbows, Option, H + H1 + H2

Models: P121LC P121 P121RC P131

1 40
Download 40 pages 33.79 Kb
Page 16
Image 16
Horizontal Venting with Two (2) 90o Elbows

INSTALLATION

Horizontal Venting with Two (2) 90o Elbows

Option

V

H + H1

A)

1' (305mm) Minimum

2' (610mm) Maximum

B)

2' (610mm) Minimum

5' (1.5m) Maximum

C)

3' (914mm) Minimum

8' (2.4m) Maximum

D)

4' (1.22m) Minimum

11' (3.35m) Maximum

E)

5' (1.5m) Minimum

14' (4.27m) Maximum

F)

6' (1.86m) Minimum

15' (4.5m) Maximum

With the above options, maximum total pipe length if 37 feet with minimum of 6 feet total vertical and maximum 15 feet total horizontal.

Please note minimum 1 foot between 90o elbows is required.

Horizontal Venting with Three (3) 90o Elbows

Option

V

H

H + H1 + H2

A)2' (610mm) Min. 1' (305mm) Max. 3' (914mm) Max.

B)3' (914mm) Min. 3' (914mm) Max. 6' (1.86m) Max.

C)

4' (1.22mm) Min.

5' (1.5m) Max.

9' (2.7m) Max.

D)

5' (1.5m) Min.

7' (2.13m) Max.

12' (3.6m) Max.

With the above options, maximum total pipe length if 37 feet with minimum of 5 feet total vertical and maximum 12 feet total horizontal.

Please note minimum 1 foot between 90o elbows is required.

Diagram 5

Diagram 3

Horizontal Venting with Two (2) 90o Elbows

Option

V

H

H + H1

A)1' (305mm) Min. 1' (305mm) Max. 3' (914mm) Max.

B)2' (610mm) Min. 3' (0.91m) Max. 6' (1.86m) Max.

C)

3' (914mm) Min.

5' (1.5m) Max.

9' (2.7m) Max.

D)

5' (1.5m) Min.

8' (2.4m) Max.

12' (3.6m) Max.

With the above options, maximum total pipe length if 37 feet with minimum of 5 feet total vertical and maximum 12 feet total horizontal.

Please note minimum 1 foot between 90o elbows is required.

Horizontal Venting with Three (3) 90o Elbows

Option

 

V + V1

H + H1

A)

2' (610mm) Minimum

3' (914mm) Maximum

B)

3' (914mm) Minimum

6' (1.86m) Maximum

C)

4'

(1.22m) Minimum

9' (2.7m) Maximum

D)

5'

(1.5m) Minimum

12' (3.6m) Maximum

With the above options, maximum total pipe length if 37 feet with minimum of 5 feet total vertical and maximum 12 feet total horizontal.

Please note minimum 1 foot between 90o elbows is required.

Diagram 4

Diagram 6

 

 

16

Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace

Page 16
Image 16
Regency P121 Installation, Horizontal Venting with Two 2 90o Elbows, Horizontal Venting with Three 3 90o Elbows, Option