INSTALLATION
CONVERSION KIT FROM NATURAL GAS TO PROPANE MODEL
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
Conversion Kit Contains:
Qty. Part # | Description |
1
1 | LP Injector (Pilot Orifice) | |
1 | * | Burner Orifice #50 |
1 | Decal "Converted to Propane" |
1
1
1)Remove the louvers and trim kit. Remove the front door.
2)Remove the logs, embers.
3)Remove the grate by lifting straight up. Remove the side brick panels (if installed). The brick panel is very fragile - handle with care.
4)Remove the burner assembly by removing the 4 Phillips head screws and then slide the burner assembly away from the orifice and lift out.
5)Pull off the pilot cap to expose the pilot orifice.
6)Unscrew the pilot orifice with the allen key and replace with the LP pilot orifice in the kit and replace pilot cap.
7)Remove burner orifice with a 1/2" wrench and discard. Use another wrench to hold on to the elbow behind the orifice.
Diagram 1: Remove the left and right screws and then slide the burner assembly away from the orifice and lift out.
Burner Orifice
8)Reinstall new burner orifice LP stamped #50 and tighten.
9)Remove and discard the 3 pressure regu- lator mounting screws (A), pressure regu- lator tower (B) and diaphragm (C).
10)Insure that the rubber gasket (D) is properly positioned and install the new HI/LO pres- sure regulator assembly to the valve using the new screws (E) supplied with the kit. Tighten screws securely.
11)Reverse steps 4) to 1).
12)Attach clear label "This unit has been con- verted to Propane" near or on the serial # decal. Attach white label "This valve has been converted from NG to LPG using SIT conversion Kit Code 0.907.202" onto the valve.
13)Replace yellow "Natural Gas" label with red "Propane" label
14)Check for gas leaks.
15)Check inlet and outlet pressures.
16)Check operation of flame control.
17)Check for proper flame appearance and glow on logs.