INSTALLATION
Vertical Venting with Two (2) 90o Elbows
| Option | V | H |
| A) | 1' (305mm) Minimum | 4' (1.22m) Maximum |
|
|
|
|
| B) | 2' (610mm) Minimum | 6' (1.86m) Maximum |
|
|
|
|
| C) | 3' (914mm) Minimum | 9' (2.7m) Maximum |
|
|
|
|
| D) | 4' (1.22m) Minimum | 12' (3.6m) Maximum |
| E) | 5' (1.5m) Minimum | 15' (4.5m) Maximum |
|
|
|
|
| F) | 6' (1.86m) Minimum | 17' (5.1m) Maximum |
|
|
|
|
With the above options, maximum total pipe length if 37 feet with minimum of 6 feet total vertical and maximum 17 feet total horizontal.
Please note minimum 1 foot between 90o elbows is required.
Diagram 9
Vertical Venting with Two (2) 90o Elbows
Option | V | H + H1 |
A) | 1' (305mm) Minimum | 2' (610mm) Maximum |
B) | 2' (610mm) Minimum | 4' (1.22m) Maximum |
C) | 3' (914mm) Minimum | 6' (1.86m) Maximum |
D) | 4' (1.22m) Minimum | 8' (2.4m) Maximum |
With the above options, maximum total pipe length if 37 feet with minimum of 4 feet total vertical and maximum 8 feet total horizontal.
Please note minimum 1 foot between 90o elbows is required.
Diagram 10
Vertical Venting with Three (3) 90o Elbows
Option | V + V1 | H | H + H1 |
A)2' (610mm) Min. 1' (305mm) Max. 2' (610mm) Max.
B)3' (914mm) Min. 4' (1.22m) Max. 5' (1.5m) Max.
C)4' (1.22mm) Min. 6' (1.86m) Max. 8' (2.4m) Max.
D) | 5' (1.5m) Min. | 8' (2.4m) Max. | 12' (3.6m) Max. |
With the above options, maximum total pipe length if 37 feet with minimum of 5 feet total vertical and maximum 12 feet total horizontal.
Please note minimum 1 foot between 90o elbows is required.
Diagram 11
18 | Regency |