Vertical Venting with Two (2) 90o Elbows

INSTALLATION

Vertical Venting with Two (2) 90o Elbows

 

Option

V

H

 

A)

1' (305mm) Minimum

4' (1.22m) Maximum

 

 

 

 

 

B)

2' (610mm) Minimum

6' (1.86m) Maximum

 

 

 

 

 

C)

3' (914mm) Minimum

9' (2.7m) Maximum

 

 

 

 

 

D)

4' (1.22m) Minimum

12' (3.6m) Maximum

 

E)

5' (1.5m) Minimum

15' (4.5m) Maximum

 

 

 

 

 

F)

6' (1.86m) Minimum

17' (5.1m) Maximum

 

 

 

 

With the above options, maximum total pipe length if 37 feet with minimum of 6 feet total vertical and maximum 17 feet total horizontal.

Please note minimum 1 foot between 90o elbows is required.

Diagram 9

Vertical Venting with Two (2) 90o Elbows

Option

V

H + H1

A)

1' (305mm) Minimum

2' (610mm) Maximum

B)

2' (610mm) Minimum

4' (1.22m) Maximum

C)

3' (914mm) Minimum

6' (1.86m) Maximum

D)

4' (1.22m) Minimum

8' (2.4m) Maximum

With the above options, maximum total pipe length if 37 feet with minimum of 4 feet total vertical and maximum 8 feet total horizontal.

Please note minimum 1 foot between 90o elbows is required.

Diagram 10

Vertical Venting with Three (3) 90o Elbows

Option

V + V1

H

H + H1

A)2' (610mm) Min. 1' (305mm) Max. 2' (610mm) Max.

B)3' (914mm) Min. 4' (1.22m) Max. 5' (1.5m) Max.

C)4' (1.22mm) Min. 6' (1.86m) Max. 8' (2.4m) Max.

D)

5' (1.5m) Min.

8' (2.4m) Max.

12' (3.6m) Max.

With the above options, maximum total pipe length if 37 feet with minimum of 5 feet total vertical and maximum 12 feet total horizontal.

Please note minimum 1 foot between 90o elbows is required.

Diagram 11