VENTING ARRANGEMENT - HORIZONTAL TERMINATIONS

INSTALLATION

VENTING ARRANGEMENT - HORIZONTAL TERMINATIONS

Regency Direct Vent System (Flex) Horizontal Terminations Only

These venting systems, in combination with the P121-1/P121LC-1/P121RC-1/P131-1 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram on page 12.

Regency Direct Vent (Flex) System Termination Kit (Part# 946-513) includes all the parts needed to install the P121-1/P121LC-1/ P121RC-1/P131-1 with a maximum run of 2 feet.

1)6-7/8" dia. flexible liner (2 ft. length)

2)4" dia. flexible liner (2 ft. length)

3)spring spacers (3)

4)thimble (2)

5)AstroCap termination cap (1)

6)screws (12)

7)tube of Mill Pac (1)

8)plated screws (8)

9)screws #8 x 1-1/2" drill point, stainless steel (4)

Notes:

1)Liner sections should be continuous without any joints or seams.

2)Only Flex pipe purchased from Regency may be used for Flex installations.

3)Regency Direct Vent System (Flex) is only approved for horizontal terminations.

Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace

13

Page 13
Image 13
Regency P121RC, P121LC, P131 installation manual Installation, Venting Arrangement - Horizontal Terminations