Troubleshooting

Troubleshooting

THERMOSTAT AND GAS SUPPLY CHECK WARNING

This troubleshooting guide has been supplied for use by qualified service personnel who have a complete under- standing of both electricity and gas.

Manual background WARNING

Label all wiring before disconnecting any wiring; to ensure correct reconnection. Failure to follow this instruction could cause improper and possible danger- ous operation, resulting in DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

THERMOSTAT AND GAS SUPPLY CHECK

No

Turn “ON” gas supply.

Is gas being supplied to the thermostat?

Yes

Is thermostat calling for heat? Run (hot) water from heater and turn adjustment knob higher. Check using a manometer at thermostat pressure tap.

Yes

Call gas company to increase gas pressure.

Is there a minimum gas pressure 4W.C. for natural gas or 10W.C. for propane (L.P.) gas?

No

Yes

GO TO SYSTEMS CHECK SECTION, PAGE 32