Installing the New Water Heater (cont’d)

5.The water heater must be electrically “grounded” by the installer. The unit will not operate unless it is prop- erly grounded. For complete grounding details and all allowable exceptions, refer to local codes or in the

absence of local codes, with the National Electrical Code, ANSI/NFPA 70 (current edition).

6.Replace the wiring junction cover using the screws provided.

Wiring Diagram

CAUTION

Label all wires prior to disconnection when servicing con- trols. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

Venting

WARNING

To insure proper venting of this gas-fired water heater, the correct vent pipe diameter must be utilized. Any additions of other gas appliances on vent with this water heater will adversely affect the operation of the water heater.

WARNING

The vent outlet must connect to the water heater exhaust out- let. The vent inlet piping must connect to the water heater air inlet. Both the water heater connections are clearly marked. Failure to read this instruction can result in DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

WARNING

The vent pipe from the water heater must be 3diameter vent pipe and must slope upward 18 inch per five linear feet.

All vent gases must be completely vented to the outdoors of the structure (dwelling).

MIN. RISE 18

PER FIVE FEET

WARNING

Obstructed or deteriorated vent systems may present seri- ous health risk or asphyxiation.

WARNING

Failure to have required clearances between water heater and combustible material will result in a fire hazard.