Typical Installation

INTAKE FOR

COMBUSTION

EXHAUST AIR

VENT TO

OUTDOORS

FLUE PRODUCTS DISCHARGE PIPE

Vacuum Relief required by some codes

(refer to local codes)

AIR INTAKE PIPE

COLD WATER INLET

Some models are equipped with

circulating loop fittings.

HOT WATER OUTLET

TEMPERED

WATER OUTLET

MIXING

VALVE

SHUTOFF VALVE

TEMPERATURE-

PRESSURE RELIEF

VALVE

*HOT (OUTLET) RECIRCULATING

LOOP CONNECTION CAN BE

INSTALLED WITHIN 360° RADIUS

DIRECTION

OF FLOW

CHECK VALVE

MARKED WITH

DIRECTION OF

FLOW ARROW

GAS

SUPPLY

7' POWER CORD (Factory supplied)

 

 

DISCHARGE PIPE

 

 

 

 

 

 

 

 

 

(Do not cap or plug)

*COLD (RETURN) RECIRCULAT-

 

PROVIDE A 6AIR GAP

ING LOOP CONNECTION MUST

 

BETWEEN THE END OF

BE INSTALLED ONLY IN THE

 

UPRIGHT POSITION

 

THE DISCHARGE PIPE

 

 

 

AND DRAIN

 

 

 

 

 

 

 

 

DIRECTION

 

 

 

 

 

OF FLOW

 

 

 

 

 

HEAT TRAP

 

 

 

 

 

*Certain models do not have these connection assemblies shipped with the water heater. They (Part #9001262) are available through the manufacturer. See “Repair Parts” section for ordering information.

This appliance has been design certified as complying with American National Standard/CSA Standard for water heaters and is considered suitable for:

Water (Potable) Heating: All models are “considered suitable for water (potable) heating.”

Water (Potable) Heating and Space Heating: Certain models are “considered suitable for water (potable) heating and space heating.” Refer to the model and rating plate of the water heater.

WARNING

When the system requires water at temperatures higher than required for other uses, the hot water system may require a means such as a mixing valve to be installed to temper the water at certain points of use. Some peo- ple are more likely to be permanently injured by hot water than others; these include the elderly, children, the infirm, or the physically/mentally handicapped. Before immersing yourself or anyone else in hot water, be sure to check the water temperature. WARNING: HOTTER WATER INCREASES THE RISK OF SCALD INJURY. (Also see “Temperature Regulation” section) Mixing valves are available at plumbing supply or hard- ware stores. Follow manufacturers instructions for installation of these valves.

WARNING

This water heater shall not be connected to any heating systems or component(s) previously used with a non- potable water heating appliance.

If this water heater is also used for space heating applica- tions, all piping and components connected to the water heater shall be suitable for use with potable water.

WARNING

Toxic chemicals such as used for treatment of boilers or non-potable water heating appliances shall never be introduced into a potable water space heating system.

NOTE: To protect against untimely corrosion of hot and cold water fittings, it is strongly recommended that di-electric unions or couplings be installed on this water heater when connected to copper pipe.

6

Page 6
Image 6
Reliance Water Heaters 606, 11-03, 184333-001 Typical Installation, Some models are equipped with Circulating loop fittings