6.2. Radio Network Setup

Setting the Unit Type

1.Select Network ä Unit Type.

2.Select from the following options:

1-BaseConfigure as a base station. This unit type receives the TOID from the data packet received through the serial port.

2-RemoteConfigure as a remote. This unit type receives the TOID from its configuration.

Setting the Unit ID (MYID)

1.Select Network ä MYID.

2.Enter a unique identification for the unit. The value must be a hexadecimal value between 0001 and FFFE. For more information about addressing and wildcards, refer to Section 5.4.

Setting the Target Unit ID (TOID)

You only need to set this parameter if the Unit Type is Remote. The system ignores this parameter if the Unit Type is Base.

1.Select Network ä TOID.

2.Enter the destination address for packets from this unit. The destination address is the MYID of the unit for which the data is intended. The value must be a hexadecimal value in the range 0000 ￿ FFFF. For more information about addressing and wildcards, refer to Section 5.4.

Setting the Active Channel

1.Select Radio ä Select Active Channel.

2.Enter the channel assignment for this unit. The value must be a number in the range 01 ￿ 64.

Setting the Receive Frequency

1.Select Radio ä Receive Frequency for Active Channel.

2.Enter the receive frequency for the active radio channel in MHz. The value must be a number in the format nnn.nnnn.

Setting the Transmit Frequency

1.Select Radio ä Transmit Frequency for Active Channel.

2.Enter the transmit frequency for the active radio channel in MHz. The value must be a number in the format nnn.nnnn.

RF Neulink

30

NL6000 User Guide

Page 30
Image 30