6.1. General Procedures

Entering Programming Mode

Perform this procedure when you need to reset any of the existing configuration parameters for the NL6000.

Note: If the Programming Mode is Disabled, you must perform this procedure within five seconds of powering on the unit.

1.Open HyperTerminal or Procomm.

2.Type …//

The Main Menu opens.

Setting the Program Mode

The Program Mode parameter determines when the operator can enter programming mode from operational mode.

1.Select Serial ä Program Mode.

2.Select from the following options:

1-DisabledEnter programming mode within five seconds of power-on. Select this option under normal operating conditions to prevent accidental resetting of parameters.

2-EnabledEnter programming mode whenever you type the key sequence …// . There must be a pause before and after the sequence. Select this option during factory configuration or during initial configuration of a unit.

Saving Configuration Changes to Flash Memory

Select E - Exit from the Main Menu to save the updated parameter settings to the unit￿s flash memory. The unit immediately begins using the new configuration.

Saving Configuration Changes Temporarily

Select C - Continue from the Main Menu to temporarily save the updated settings for the current operating session. The configuration is not saved to flash memory. You can revert to the prior configuration by cycling power to the unit.

Reverting to the Prior Configuration

Select R - Restart from the Main Menu to ignore the changes you made and revert back to the prior configuration.