103
TECHNICAL REFERENCE
8. TECHNICAL
REFERENCE
Registered
5 Select OK
02 :1110 1000 OK
6

T o toggle the value of a single bit, press

the number on the numeric keypad that

corresponds to the number of the bit

you wish to change.

E.g. press to change bit 3.
7

Press . The display opposite will

flash briefly on the display and then the

function menu will reappear.

Note

Do not carry out any operations while “Reg-
istered” appears on the display.
8
Do one of the following:
Enter another function number.
Press Help/Function to return to standby mode.
SWITCH 00 (1/2)
Explanation
Width scanned when faxing
a document
Display “Original left on
glass.” Warning when scan-
ning from the ADF and an
original is left on the expo-
sure glass
Maximum length of docu-
ment when scanning from
the ADF
Automatically print the
T ransmission Result Report
after every successful trans-
mission
Default
210mm (A4)
Yes
400mm
No
Bit
7
6
5
4
Available
Settings
0: 210 mm (A4)
1:
216mm (LT/LG)
0: Yes
1: No
0: 400mm
1: 1200mm
0: No
1: Yes
Notes
This setting takes effect
from the next power on.
This setting takes effect
from the next power on.
Please wait

User Parameter Switch Summary

The following tables summarize the User Parameter bit switches and their

meanings.