![FLUE SIZES:](/images/new-backgrounds/38283/3828349x1.webp)
LOCATION
Do not flue into natural draught flues or fireplaces, this unit can only be used with one of the six types of Rinnai flue kits.
Do not flue unit into other rooms. Flue terminal must be outside.
Flue may be positioned directly under opening windows, with a minimum clearance of 300mm.
FLUE SIZES:
6 Flue lengths are available. |
|
| ||
S | flue suits wall | 75 | - | 115 mm |
A | flue suits wall | 115 | - | 240 mm |
B | flue suits wall | 240 | - | 400 mm |
C | flue suits wall | 400 | - | 600 mm |
D | flue suits wall | 600 | - | 800 mm |
E | flue suits wall | 800 | - | 1000 mm |
SNOW AREAS
Snow
In areas subject to heavy snowfall, keep snow clear of flue terminal at all times.
STANDARD INSTALLATION OF FLUE MANIFOLD.
Diagram below shows minimum clearances and distances from obstructions. Also check local regulations.
Flammable |
| |
Non |
| |
Flammable | 600mm | |
Wall | ||
| ||
300mm |
| |
375mm | ||
600mm | Opposite | |
| Wall | |
| Floor |
Side Clearances
300mm
Obstruction
FIT BACK COVERS (SIDES ONLY)
Fit back covers (sides only) as shown below.
Secure with
Screws
Secure with Screws
GAS CONNECTION
Fit suitable copper flare elbow to appliance inlet.