FLUE EXTENSION KITS
1.How to connect the flue pipes.
To connect the rigid flue pipes fit the male end into the female end and clamp with pipe stopper A to prevent slipping. The flue pipe can be telescoped to the required length: DO NOT CUT IT.
| Exhaust pipe |
| Female end |
| Male end |
|
| Exhaust pipe |
|
| |
| Fit inside | Connect bent pipe |
|
| |
|
|
|
| ||
|
| Fit inside | |||
Female end | Male end | Female end | Male end |
|
|
|
|
| Pipe stopper B |
|
|
Pipe stopper B
Pipe stopper A
Pipe stopper A
2.How to connect air intake hose.
Screw one air intake hose into socket of the appliance’s main air intake hose. If this is not long enough then join air intake hoses together by screwing them both half way into a hose joint socket.
Important: The PVC air line is longer than the flue line and may need to be cut down to size. Be sure to thoroughly debur all rough edges.
Air intake hose | Air intake hose | |
Hose joint | ||
| ||
Screw in counterclockwise | Air intake elbow | |
Main unit air intake hose | ||
|
3.Affixing the air intake hose and flue pipe. NOTE: Maintain 25mm clearance between flue pipe and combustible materials (0mm clearance between flue pipe and
Screw A | Pipe clamp | Screw A | Pipe clamp |
Air intake | Air intake |
| |
hose |
| Exhaust pipe | |
hose |
| ||
Wall | Exhaust pipe Wall | Nut | |
Screw B | Wall fixture |
Set the air intake hose and flue pipe into the pipe clamps, screw the clamp onto the wall fixture, and affix to the wall with screw B.
The air intake hose and flue pipe can also be screwed onto the wall using the pipe clamp and the nut.
4. How to use the bent pipe.
Adjust the angle
With the flue pipes inserted into the ends, bend the bent pipe to the angle required for installation.
This part is usually used for curves or connection to vent terminal.