FLUE MANIFOLD POSITION

LOCATION

Do not install the heater in an unusually dusty area.

FLUE MANIFOLD POSITION

Important

The centre of the hole for the flue manifold must only be drilled in the position indicated on the diagram below.

Use a flue guard if the terminal is easily accessible to children.

Check local regulations.

Guards are available as an optional extra.

Guard

Floor must be level.

Do not use electrical extension cords to connect the unit to a power supply.

Keep the power cord away from the flue.

Drill Hole 80mmφ thru wall

115

Flue Elbow

677

265

217

All measurements are taken from the extremities of the appliance.

Before drilling the flue hole, check for water and gas pipes as well as electric cables.

For weatherboard walls drill through centre of the weatherboard from the outside, then drill from inside through the plaster board.

WALL MOUNTING BRACKETS

Place top back spacer.

Mark the position of the top edge of the top spacer on the wall.

Move the heater away from the wall.

Mark the centre lines 30mm down from the top edge mark, and 40mm in from the left and right hand sides of the top spacer.

Attach wall brackets at the marked positon. Remove right hand back spacer.