BLACKHEAT® INSTALLATION OPERATION AND SERVICE MANUAL
SECTION 4: SPECIFICATIONS
4.1Material Specifications
4.1.1Combustion and Tubes
First 3 meters
4.1.2Reflectors
NS3 H14 aluminium or 1.4016 2R stainless steel (option)
4.2Heater Specifications
4.2.1Sequence Controller
Fully automatic single try direct spark 100% shut off ignition flame rectification module
4.2.2Electrical
Rating: 230V, 50 Hz, single phase, 1 amp
Connection: 3 pin moulded plug
4.2.3Gas Supply
Connection: Rc1/2 (1/2" BSP int)
Natural : Nominal - Inlet 1.13kPa Maximum - Inlet 5.0 kPa
ULPG Gas (Propane or Propane/Butane mix): Nominal - Inlet 2.75 kPa
Maximum - Inlet 5.00 kPa
4.3Venting Specifications
4.3.1 Fans |
|
Model: Torin DSF | |
Model: Torin DSA | |
Model: Magnetek JF1G |
Consult the manufacturer for availability of alternate fans.
4.3.2Flue
When fitted, the flue must be 100 mm, or greater in diameter, and must conform to AS5601/AG 601. The flue
must be self supporting. Inlet must be 100 mm diameter.
4.4Suspension Specifications
Galvanised straight link welded chain.
Working load of 340 kg (750 lbs)
4.5Controls Specifications
Time switches, thermostats, etc. can be wired into the electrical supply. External controls supplied as an optional extra.
8