SECTION 5: MAJOR COMPONENT DESCRIPTIONS
SECTION 5: MAJOR COMPONENT DESCRIPTIONS
Burner (shown with Tube Gasket)
Must be installed with the flame observation window facing down.
Reflector (Aluminium or Stainless Steel) Alternate overlap as shown on overview. Minimum overlap is 18 cm.
Burner Tube | Tube |
Supplied in 3m lengths. Burner | Heat Treated Aluminized Tube |
tube is always the first tube after | Supplied in 3m lengths. |
the burner. |
|
Tube and Reflector Hanger with Tube Clamp Package Position this hanger no more than 20cm away from the burner assembly. Recommended 100mm.
Fan Tube with Internal Swirler Fan tube is
always the last tube on the heater where the fan is attached.
Coupling Assembly with Lock
Tube and Reflector Hanger Suspend system from these hangers.
Reflector Support Strap, Wire
Form & #8 x 3/4 (3.9 x 19mm)
Screw
Flex Gas Line
Tee
Assembly
Assembly
Reflector End Cap
Punch out center section to accommodate heat exchanger tube.
Fan Assembly (Includes Flange) Fan Assembly is attached to the last section of heat exchanger tubing (Fan Tube).
Damper Flange Assembly
For use on Multiburner Systems.
Fan Flange Assembly
and Screws
| Turnbuckle | |
| Adjuster | |
| ||
Support | Bow | |
Bracket | ||
Shackle | ||
|
11