3.2Clearance Data -

NOTE: 1. All dimensions are from the Tube surface.

2.Clearances B, C and D can be reduced by 50% after 7 m of tubing downstream from the burner.

3.All measurements are in Millimeters.

FIGURE 2: LINEAR , HORIZONTAL MOUNTS

A

C

B

D

Model A B C

D

BH15

150

890

1570

890

BH20

150

970

1650

970

BH25

150

970

1650

970

BH30

150

1020

1780

1020

BH35

150

1170

1930

1170

BH40

150

1220

1970

1220

BH45

200

1280

2010

1280

BH50

200

1330

2080

1330

FIGURE 3: LINEAR , ONE SIDE REFLECTOR

A

C

B

D

Model

A

B

C

D

BH15

150

230

1580

1200

BH20

150

230

1760

1380

BH25

150

230

1760

1380

BH30

150

230

1930

1500

BH35

150

230

2090

1660

BH40

150

230

2130

1710

BH45

200

230

2160

1760

BH50

200

230

2240

1860

FIGURE 4: LINEAR, TWO SIDE REFLECTORS

A

C

B

D

Model

A

B

C

D

BH15

150

590

1660

590

BH20

150

640

1810

640

BH25

150

640

1810

640

BH30

150

690

1960

690

BH35

150

820

2110

820

BH40

150

860

2160

860

BH45

200

890

2210

890

BH50

200

1020

2320

1020

FIGURE 5: LINEAR, 45° MOUNT

A

C

B D

Model

A

B

C

D

BH15

200

200

1500

1370

BH20

200

200

1660

1520

BH25

200

200

1660

1520

BH30

250

200

1860

1630

BH35

250

200

1960

1750

BH40

275

200

2030

1820

BH45

300

200

2110

1880

BH50

300

200

2160

2000