Step 7.5 Turbulator Installation

TF-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL

Step 7.5 Turbulator Installation

TurbulatorManual background

Section

TurbulatorTab

Adapter

Description

Part Number

Turbulator Adapter

03051503

Turbulator Section

03051504

Tube

91409XXX

Turbulator must be installed in the last standard section of tube.

 

Turbulator Installation

 

Model

Tube Section

 

TF-120

2nd 10' Section Each Side

T

TF-160

2nd 10' Section Each Side

w

TF-200

3rd 10' Section Each Side

i

s

 

 

t

TF-250

N/A

 

 

TF-300

N/A

 

TF-350

N/A

 

TF-380

N/A

Model

Each Side

TF-120 & TF-160

1 - 03051503

4 - 03051504

 

TF-200

1 - 03051503

2 - 03051504

 

Pull String

Fold tab around outside

of tube nearest to the vent to Manual backgroundManual background hold turbulator in place.