NOTE: 1. All dimensions are from the surfaces of all tubes, couplings and elbows.

2.Clearances B, C and D can be reduced by 50% after 25' (7.5 m) of tubing downstream from where the burner and burner tube connect.

FIGURE 3: STANDARD REFLECTOR

 

 

 

 

 

 

 

 

 

 

(inches)

 

 

(centimeters)

 

 

 

 

 

 

 

 

 

Model

A

B

C

D

A

B

C

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TF-120

6

35

63

35

16

89

161

89

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TF-160

6

38

66

38

16

97

168

97

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TF-200

6

40

71

40

16

102

181

102

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TF-250

6

46

77

46

16

117

196

117

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TF-300

6

50

80

50

16

127

204

127

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TF-350

8

52

82

52

21

133

209

133

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TF-380

8

52

82

52

21

133

209

133

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIGURE 4: ONE SIDE REFLECTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

(inches)

 

 

(centimeters)

 

 

 

 

Model

A

B

C

D

A

B

C

D

A

 

 

TF-120

6

9

63

47

16

23

161

120

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TF-160

6

9

70

54

16

23

178

138

 

 

 

TF-200

6

9

77

59

16

23

196

150

C

B

D

TF-250

6

9

83

65

16

23

211

166

 

 

 

 

 

TF-300

6

9

86

69

16

23

219

176

 

 

 

TF-350

8

9

88

73

21

23

224

186

 

 

 

TF-380

8

9

88

73

21

23

224

186

FIGURE 5: TWO SIDE REFLECTORS

 

 

 

 

 

 

 

 

 

 

 

 

 

(inches)

 

 

(centimeters)

 

 

 

 

Model

A

B

C

D

A

B

C

D

A

 

 

TF-120

6

23

66

23

16

59

168

59

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TF-160

6

25

72

25

16

64

183

64

 

 

 

TF-200

6

27

78

27

16

69

199

69

C

B

D

TF-250

6

32

84

32

16

82

214

82

 

 

 

 

 

TF-300

6

35

88

35

16

89

224

89

 

 

 

TF-350

8

40

91

40

21

102

232

102

 

 

 

TF-380

8

40

91

40

21

102

232

102

6

Page 12
Image 12
Roberts Gorden TF-250, TF-350, TF-300, TF-120, TF-200, TF-160, TF-380 service manual Standard Reflector, ONE Side Reflector

TF-380, TF-250, TF-160, TF-200, TF-120 specifications

Roberts Gorden is renowned for its innovative and efficient heating solutions, particularly through its TF series of forced air heaters. The TF-120, TF-200, TF-250, TF-300, and TF-350 models are designed to cater to a variety of applications, offering flexibility, efficiency, and user-friendly operation.

The TF series features advanced combustion technology that ensures high thermal efficiency, significantly reducing fuel consumption while providing optimal heating performance. The heaters utilize a state-of-the-art burner design that allows for quiet operation and minimal emissions, aligning with modern environmental standards.

A standout feature across the TF series is the digital control system, which offers precise temperature management and programmability. The LCD interface allows users to easily adjust settings, monitor performance, and receive diagnostic feedback, enhancing reliability and operational efficiency. The automated controls save energy by modulating operation to only what is necessary to maintain the desired temperature.

The design of the TF-120, TF-200, TF-250, TF-300, and TF-350 models prioritizes durability and ease of installation. Built with rugged materials, these heaters can withstand demanding industrial environments while ensuring long service life. The compact footprint of each model allows for flexible placement, making them suitable for various facilities, including warehouses, workshops, and retail spaces.

Safety is a core attribute of the TF series. Each heater comes equipped with multiple safety features, including over-temperature protection, flame failure detection, and safety shut-off valves. This commitment to safety ensures that users can operate the heaters with peace of mind.

In terms of output capacity, the TF models range to accommodate different heating needs. The TF-120 is perfect for smaller spaces, while the TF-350 caters to larger areas, providing versatility for various industrial applications. Additionally, the heaters can be powered by natural gas or propane, offering flexibility in fuel choice based on user preference or availability.

In summary, Roberts Gorden's TF series—TF-120, TF-200, TF-250, TF-300, and TF-350—delivers a well-rounded heating solution with features such as high thermal efficiency, advanced digital controls, robust safety mechanisms, and a durable design. The adaptability and efficiency of these heaters make them a preferred choice for businesses seeking reliable heating solutions in diverse environments.