Roberts Gorden TF-380, TF-350, TF-300, TF-120, TF-200 Electrical Cord or Flexible Conduit Burner

Models: TF-380 TF-250 TF-160 TF-200 TF-120 TF-300 TF-350

1 72
Download 72 pages 34.8 Kb
Page 55
Image 55
Electrical Cord or

SECTION 11: WIRING

11.5 Electrical Connection to the Burner

Electrical Cord or

Flexible Conduit

Burner

Connect wires together with

suitable approved wire connections.

Green

White

Black

 

 

 

 

 

Green to Gnd.

 

 

 

 

 

 

White to L2

 

 

 

Black to L1

 

 

Internal Wire Bundle

L1

L2

Gnd.

 

Wire Connector Conduit Hole

49

Page 55
Image 55
Roberts Gorden TF-380, TF-350, TF-300, TF-120, TF-200, TF-160, TF-250 service manual Electrical Cord or Flexible Conduit Burner