Roberts Gorden TF-120 General Specifications, 15.1Material Specifications 15.1.1 Reflectors

Models: TF-380 TF-250 TF-160 TF-200 TF-120 TF-300 TF-350

1 72
Download 72 pages 34.8 Kb
Page 65
Image 65
SECTION 15: GENERAL SPECIFICATIONS

SECTION 15: GENERAL SPECIFICATIONS

SECTION 15: GENERAL SPECIFICATIONS

15.1Material Specifications 15.1.1 Reflectors

.024 Aluminum

(Optional .024 Stainless Steel Type 304)

15.2Heater Specifications 15.2.1 Ignition

Fully automatic, three-try, direct spark, electronic ignition control, 100% safety shut-off.

15.3 Suspension Specifications

Hang heater with materials with a minimum working load of 75 lbs (33 kg). See Page 17, Figure 14.

15.4 Controls Specifications

Time switches, thermostats, etc. can be wired into the electrical supply. External controls supplied as an optional extra.

General Specifications for heaters are as follows:

Side View

 

Length "A"

 

 

 

 

 

 

 

Reflector

 

 

 

 

23.5"

 

 

 

 

 

(60 cm)

 

 

 

 

End View

 

 

 

 

 

13.75"

 

 

 

 

 

(35 cm)

 

 

 

 

 

9.5"

 

 

 

 

 

(24 cm)

 

 

 

 

 

 

 

 

Length "A"

 

 

 

Length “A” Each Side

Recommended

 

Heat Input Rate

Minimum

Minimum Mounting Height*

Model

(Btu/h) X (1000)

Linear

U-Tube

Space

Spot

TF-120

120

20' (6 m)

11'6" (4 m)

12' (4 m)

9' (3 m)

TF-160

160

20' (6 m)

11'6" (4 m)

15' (5 m)

11' (3 m)

TF-200

200

30' (9 m)

16'6" (5 m)

15' (5 m)

12' (4 m)

TF-250

250

40' (12 m)

21’ 6" (7 m)

20' (6 m)

15' (5 m)

TF-300

300

50' (15 m)

26'6" (8 m)

20' (6 m)

20' (6 m)

TF-350

350

50' (15 m)

26'6" (8 m)

25' (8 m)

23' (7 m)

TF-380

380

60' (18 m)

31'6" (10 m)

25' (8 m)

23' (7 m)

*See Page 5, Section 3 for clearances to combustibles.

 

 

GAS PRESSURE AT MANIFOLD:

PIPE CONNECTION:

 

 

Natural Gas:

3.5" wc

3/4" NPT

 

 

LP Gas:

10.5" wc

GAS INLET PRESSURE:

 

 

DIMENSIONS:

 

Natural Gas:

5.0" wc

Minimum

Vent Connection Size:

 

16.0" wc

Maximum

 

4" (10 cm) or 6" (15 cm)

LP Gas:

12.0" wc

Minimum

Outside Air Connection Size:

 

16.0" wc

Maximum

 

4" (10 cm) or 6" (15 cm)

ELECTRICAL RATING (ALL MODELS):

 

Refer to figure above for dimensional information.

120V - 60 Hz., 1.0 Amp

 

 

59

Page 65