37
Chapter 1 Making a performance/Creating a patch
Chapter 1
Notes on Tempo Sync
• Tempo Sync is not applicable to waves of which:
1.
Type (in WAVE SETUP in Wave Edit -> p. 45) is SINGLE.
2.
Tempo is not within the range from 20 to 260 although Type is PHRASE.
In this event, "---" is indicated for Tempo on the screens on Beat (in WAVE SETUP in Wave Edit -> p. 46) and on Meas (in
WAVE SETUP in Wave Edit -> p. 46).
3.
Reverse (in WAVE SETUP in Wave Edit -> p. 46) is set to ON.
• The wave tempo is variable within the range from 50% to 130%. If Sync Tempo (in PATCH COMMON -> p. 37) exceeds this
range, the wave tempo is doubled or halved so that it can stay within the range.
• When Tempo Sync is applied, there may be some outstanding noise.
EFFECTS How to set up the EFFECTS.
Press PAGE buttons to change the parameter and press [-]/[+] to change the value.
For details on parameters of effects, see “Effect List” (p. 92).
PATCH COMMON Set the parameters common to the whole patch.
Set the following parameters. Press PAGE buttons to change the parameter and press [-]/[+] to change the value.
6 PAD 6 65(F4) 13 FOOT SW 2 72 (C5)
7 PAD 7 66(F#4)
Parameter Value Descriptions
Sync Tempo
=20–260 Set the sync tempo. When tempo sync is on (with Tempo Sync in PAD CONTROL set to ON ->
p. 36), the tempo of the waves assigned to the pads is synchronized with this tempo.
* The pad indicator is lit when Tempo Sync in PAD CONTROL is set to ON for the correspond-
ing pad/trigger.
* If you hold down [SHIFT] and hit a pad, the value of Tempo Sync in PAD CONTROL is
switched (between ON and OFF).
* For notes on Tempo Sync, see the top of the page.
* You can also define the tempo by controlling the intervals at which you hit a pad or depress
a foot switch. (Tap Tempo: Ctrl SW in CONTROL SW in Setup Edit -> p. 79)
Patch Level 0–127 Specify the volume of the patch.
Name Patch name Give a name to the patch. A name can have a maximum of eight characters. Press PAGE buttons
to move the cursor below the name and press [-]/[+] to change the character at the cursor.
* If you hold down [+] and press [-], or hold down [-] and press [+], the character changes
quickly.
* Hold down [SHIFT] and press [>] to insert a character, or hold down [SHIFT] and press [<]
to delete a character.
* Press [FUNC] to switch a letter between uppercase and lowercase.
* If you hold down [SHIFT] and press [+], the character is changed in the order of “A”, “a”,
“0,” “!” and a space character. If you hold down [SHIFT] and press [-], the character is
changed in the reverse order.
Number Playing Surface Initial Value Number Playing Surface Initial Value
If you hold down [SHIFT] and press [FUNC], the parameter is reset to its initial value (except on the “Name” screen).
SPDS_e.book 37ページ 2004年4月19日 月曜日 午前9時58分