Appendix D. Status Connect / Failure Reason Summary
Reason | Description | Action |
Can’t Find | Unable to communicate | Change invalid starting |
Computer | to the computer that’s | computer number, |
| being connected to. | incorrect expansion |
|
| cable placement or |
|
| power up expansion |
|
| Unit. |
|
|
|
Computer is | Another user is | Wait for the private |
Private | connected in private | user to disconnect and |
| mode. | retry the connect |
|
| request. |
|
|
|
No Response | Communications error. | Cycle power to the |
|
| UltraMatrix switch |
|
| where the CPU is |
|
| attached. |
|
|
|
Not in Access | A user profile specifies a | Connect to another |
Group | group without access to | computer, use another |
| this computer. | group, or include the |
|
| computer in the user’s |
|
| group. |
|
|
|
Out of Range | Attempt to connect to a | Connect to a computer |
| computer with a number | with a lower number |
| greater than the | than the maximum or |
| maximum computer | reconfigure all Units |
| parameter. | with a higher maximum |
|
| computer number. |
|
|
|
Queue Full | The Maximum number of | Wait until a user |
| KVM stations is already | disconnects from the |
| connected to the CPU | CPU |
|
|
|
Unknown | Attempt to connect to a | Change request to |
Computer | computer number greater | another computer |
| than the Maximum | number. |
| computer number |
|
|
|
|
Unknown Reason | Internal error occurred | Cycle power on all |
| during | Units affected. |
| connect/disconnect. |
|
|
|
|
ULTRAMATRIX E-SERIES MANUAL