4. Technical Specifications

4. Technical Specifications

4.1. Power Supply Specifications

Power

Input Range

Internal

Max. Power

Max Power

Connections

Supply Type

Min

Max

Fuse Rating

Consumptiona

Output

HI

88 VDC

300 VDC

2A(T)b

52W Max

42W

Screw

 

 

85 VAC

264 VAC

terminal block

 

 

 

 

 

 

 

 

 

 

 

HIP

88 VDC

300 VDC

2A(T)b

52W Max

42W

Pluggable

 

 

85 VAC

264 VAC

terminal block

 

 

 

 

 

 

 

 

 

 

 

24

10 VDC

36 VDC

2A(T)b

52W Max

42W

Screw

 

 

 

 

 

 

terminal block

24P

10 VDC

36 VDC

2A(T)b

52W Max

42W

Pluggable

 

 

 

 

 

 

terminal block

48

36 VDC

72 VDC

2A(T)b

52W Max

42W

Screw

 

 

 

 

 

 

terminal block

48P

36 VDC

72 VDC

2A(T)b

52W Max

42W

Pluggable

 

 

 

 

 

 

terminal block

aPower consumption varies based on configuration.

b(T) denotes time-delay fuse.

Table 4.1. Power Supply Specifications

4.2. Critical Alarm Relay Specifications

Voltage

Current

30VDC

5A

 

 

250VAC

6.25A

 

 

Table 4.2. Form C Contact Relay Specifications

4.3. Copper Ethernet Port Specifications

The RX1510 can be ordered with several different modules which contain 10/100Tx or 10/100/1000Tx Ethernet ports. All copper Ethernet ports have the following specifications:

Parameter

Specification

Notes

Speed

10/100 or 10/100/1000 Mbps

Auto-negotiating

 

 

 

Duplex

FDX / HDX

Auto-negotiating

 

 

 

Cable-Type

> Category 5

Shielded/Unshielded

 

 

 

Wiring Standard

TIA/EIA T568A/B

Auto-Crossover, Auto-Polarity

 

 

 

Max Distance

100 m

 

 

 

 

Connector

RJ45

 

 

 

 

Isolation

1.5kV

RMS 1-minute

 

 

 

Table 4.3. Copper Ethernet Port Specifications

RuggedCom® RuggedBackbone™

39

RX1510 Installation Guide Rev 104

Page 39
Image 39
RuggedCom RX1510 manual Technical Specifications, Power Supply Specifications, Critical Alarm Relay Specifications