Runco PL-50XA manual Serial Communications, Command Parameter Value Description Min/max Stored?

Models: PL-50XA

1 68
Download 68 pages 9.96 Kb
Page 57
Image 57

6. Serial Communications

To interface the PlasmaWall with a home theater automation/control system or a PC running terminal emulation software, connect it to the RS-232 output of the DHD Controller as shown in Figure 3-4.Connect your control system or PC to the RS-232 input of the DHD Controller as shown in Figure 3-9.

Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop bit and no flow control. Set the baud rate to 19200, to match that of the DHD Controller RS-232 port.

Serial commands to the DHD Controller take the following form:

Commands are not case-sensitive.

For a single command that takes no parameters, type the command followed by a carriage return; for example, to set the aspect ratio to Letterbox, type

LETTERBOX <Return>.

For a single command that takes a parameter, type the command, a space or a comma and the desired value followed by a carriage return; for example, to set the brightness to -10, type BRIGHTNESS -10<Return> or

BRIGHTNESS,-10 <Return>.

You can also send a string of multiple commands on a single line, separated by commas. For example, COMPOSITE,BRIGHTNESS 100,ANAMORPHIC <Return> switches to the Composite video input, sets the brightness to 100 and sets the aspect ratio to Anamorphic. Command strings can be up to 255 characters long.

Table 6-1lists the RS-232 command set. The “Parameter (min/max)” column shows the valid parameter ranges, or “NA” for commands that take no parameters.

When you enter a valid command, the DHD Controller executes it and acknowledges it with a plus sign on the command line (+ >). When you enter an invalid command -- one that is misspelled or followed by values outside the valid range for that command -- the DHD Controller ignores it and returns a minus sign (- >).

6.1

RS-232 Connection and Port Configuration

6.2

Serial Command Syntax

Table 6-1. Serial Commands

Command

Parameter

Value

Description

(min/max)

Stored?

 

 

 

 

 

 

POWER

0/1

NA

Turns display on and off

 

 

 

 

ON

NA

NA

Turns display on

 

 

 

 

OFF

NA

NA

Turns display off

 

 

 

 

COMPOSITE

NA

YES

Selects the Composite video input

 

 

 

 

SVIDEO1

NA

YES

Selects the S-Video 1 input

 

 

 

 

SVIDEO2

NA

YES

Selects the S-Video 2 input

 

 

 

 

COMPONENT

NA

YES

Selects the Component input

 

 

 

 

Runco PlasmaWall Owner’s Operating Manual

47

Page 57
Image 57
Runco PL-50XA manual Serial Communications, Command Parameter Value Description Min/max Stored?