Samsung 3759 technical manual Testing the drainage

Models: 3759

1 270
Download 270 pages 30.27 Kb
Page 247
Image 247

Note If a concentrated drain hose is installed, refer to the figure below.

Air ventilation

Drain clamp

 

100mm or more

1/100 or more slope

Concentrated drain hose

Testing the drainage

You should test the drainage after completing the installation.

Prepare a little water about 2.0 liter.

1) Remove two screws on the cover water supply intake and pull out the cover.

Cover water supply intake

2) Pour water into the indoor unit as shown in figure.

Note If you do not pour water inside the water supply intake, water may spill from the indoor unit.

3) Confirm that the water flows out through the drain hose.

Note You can check the drainage only when the air conditioner is in cool mode.

4) Reassemble the cover drain pump and the screws.

Note For installation of another drain hose, refer to an appropriate installation manual.

V21

Page 247
Image 247
Samsung 3759 technical manual Testing the drainage