GE 60-960-95 SIA System Requirements, Shortcut #, Function, Programming, Testing, Default

Models: 60-960-95

1 104
Download 104 pages 42.3 Kb
Page 7
Image 7
SIA System Requirements

Immediate Beeps set to on

UL 98 Options set to on

Receiver Failure set to on (if wireless devices are used)

Siren Verify set to on

RF TX Timeout set to 4 hours (if system includes a built in or SuperBus 2000 RF Receiver and wireless smoke sensors)

Sleep Time set to off

Siren Timeout set to 4 minutes or more

Two Trip Error set to off

Disable Trouble Beeps set to off

UL 1023 & 985 24-Hour Backup

For 24-hour backup, the total current draw for all connected devices is limited to 190 mA (during normal standby conditions) using a 7.0 AH battery.

Note

UL requirements take prior- ity over SIA requirements.

SIA System Requirements

SIA system requirements are the same as those described for a UL Listed Basic System on page 1, plus:

If multiple annunciation is required, use Hardwire Siren part no.13-046.

SIA Setting Requirements

The following table describes programming requirements to meet ANSI-SIA CP-01.

Shortcut #

Function

Programming

Testing

Default

Required Setting

 

 

 

Page

Page

Setting

 

 

 

 

 

Reference

Reference

 

 

 

 

 

 

 

 

 

 

 

0004

SIA False Alarm

25

63

On

On

 

Reduction

 

 

 

 

 

 

 

 

 

 

 

 

 

partition 1: 0013

Exit Extension

26

63

On

On

partition 2: 0023

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

partition 1: 0014

Auto Stay Arming

26

63

On

On

partition 2: 0024

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

partition 1: 0017

Duress Code

27

63

Disabled

Disabled

partition 2: 0027

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02005

Dialer Abort

33

63

On

On

 

 

 

 

 

 

 

 

02006

Dialer Abort Delay

33

63

30 Sec.

15-45 sec.

 

 

 

 

 

 

 

 

02007

Cancel Message

33

63

On

On

 

 

 

 

 

 

 

 

02009

Call Wait Cancel

34

63

Disabled

On if reporting to central station and

 

 

 

 

 

 

customer has call waiting service

 

 

 

 

 

 

 

 

partition 1: 0310

Entry Delay

37

63

30 sec.

30-240 sec.

partition 2: 0320

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

partition 1: 0311

Exit Delay

37

63

60 sec.

45-184 sec.

partition 2: 0321

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

06014

Swinger Limit

43

63

1

1

 

 

 

 

 

 

 

 

 

1100

Smoke Verify

54

63

Off

On if smoke alarms are

 

 

 

 

 

 

programmed into system

 

 

 

 

 

 

 

 

N/A

Cross Zoning

83

63

Disabled

Enabled for zones with a high

 

 

 

 

 

 

probability of false alarms

 

 

 

 

 

 

 

 

 

The following table describes non-programmable (hard coded) system operation as required to

 

meet ANSI-SIA CP-01 and is provided only for your reference.

 

 

 

 

 

 

 

 

 

 

Function

 

Operation

 

 

 

 

 

 

 

 

 

 

 

Disarm During Entry Delay

 

Enter Code Only (or 1 + CODE)

 

 

 

 

 

 

 

 

 

Concord Ultra

2

Page 7
Image 7
GE 60-960-95 SIA System Requirements, Shortcut #, Function, Programming, Testing, Default, Required Setting